Laserfiche WebLink
<br />Page 33 of 42 <br /> <br />5. Actuated Signal Controllers & Fixed-timed Controllers: <br />□ Proper operation of front panel displays <br /> □ Detectors picking up vehicles (or pedestrians) <br /> □ Detector putting calls into proper controller phase <br />□ Controller timing operating correctly – all red, yellow, passage, min. initial, pedestrian clearance <br />□ Switches in correct position as per timing sheet <br />□ Load switches secure and set properly <br />□ Accessory equipment functioning properly <br />6. Signal Controller Cabinet: <br />□ Mounted securely to pedestal, pole, or foundation <br />□ External conduit mounted securely if present <br />□ Oil door hinges <br />□ Proper size fuse or breaker <br />□ Check to see if convenience bulb works <br />□ Clocks: check programming and time (including day of week) <br />□ Properly size interconnect fuses <br />□ Check flasher contacts <br />□ Ground wire connections snug <br />□ Sign, put time and date on maintenance card <br />□ Clean cabinet, change filters <br />□ Check cabinet to be waterproof <br />□ Check cabinet condition - note if painting is necessary <br />□ Cabinet documentation confirmed present <br />1. Timing sheet present <br />2. Trouble call card present