My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - Water Treatment Chemicals 2021-2022 - Alexander Chemical Corporation
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2021
>
Opening of Bids
>
Opening of Bids - Water Treatment Chemicals 2021-2022 - Alexander Chemical Corporation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2021 4:30:40 PM
Creation date
4/14/2021 4:28:29 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
4/13/2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Fire fighting Allow gas to burn if flow cannot be shut off immediately. Apply water from safe distance to cool <br />equipment/instructions container and protect surrounding area. In case of fire: Stop leak if safe to do so. Do not move <br />cargo or vehicle if cargo has been exposed to heat. ALWAYS stay away from tanks engulfed in <br />flame. Move containers from fire area if you can do so without risk. Do not direct water at source of <br />leak or safety devices as icing may occur. Use water spray to cool unopened containers. Do not <br />get water inside containers. Withdraw immediately in case of rising sound from venting safety <br />device or any discoloration of tanks due to fire. For massive fire in cargo area, use unmanned <br />hose holder or monitor nozzles, if possible. If not, withdraw and let fire burn out. <br />Specific methods Use standard firefighting procedures and consider the hazards of other involved materials. Cool <br />containers exposed to flames with water until well after the fire is out. <br />General fire hazards May intensify fire; oxidizer. <br />6. Accidental release measures <br />Personal precautions, <br />Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of <br />protective equipment and <br />low areas. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). <br />emergency procedures <br />Wear appropriate protective equipment and clothing during clean-up. Avoid breathing gas. <br />Emergency personnel need self-contained breathing equipment. Do not touch damaged <br />containers or spilled material unless wearing appropriate protective clothing. Ventilate closed <br />spaces before entering them. Local authorities should be advised if significant spillages cannot be <br />contained. For personal protection, see section 8 of the SDS. <br />Methods and materials for <br />If this gas leaks without igniting, extreme caution must be used; flammable or explosive mixtures <br />containment and cleaning up <br />with air may be formed. Extinguish all flames in the vicinity. This product is miscible in water. Stop <br />leak if you can do so without risk. Use water spray to reduce vapors or divert vapor cloud drift. <br />Isolate area until gas has dispersed. Dike far ahead of spill for later disposal. Prevent entry into <br />waterways, sewer, basements or confined areas. Following product recovery, flush area with <br />water. For waste disposal, see section 13 of the SDS. <br />Environmental precautions <br />Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all <br />environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into <br />drains, water courses or onto the ground. Runoff from fire control or dilution water may cause <br />pollution. <br />7. Handling and storage <br />Precautions for safe handling Do not handle, store or open near an open flame, sources of heat or sources of ignition. Protect <br />material from direct sunlight. Keep away from combustible material. Contents under pressure. <br />Keep reduction valves free from grease and oil. Valve protection caps must remain in place unless <br />container is secured with valve outlet piping to use point. Close valve after each use and when <br />container is empty. Do not drop, drag, slide or roll cylinders on their sides. Use a suitable hand <br />truck to move gas containers. Use a pressure reducing regulator when connecting container to <br />piping or systems. Never insert an object (e.g. wrench, screwdriver, pry bar) into cap openings. <br />Use an adjustable strap wrench to remove over -tight or rusted caps. Open valve slowly. Do not <br />use gas directly from containers. Do not heat container by any means to increase the discharge <br />rate of product from the container. <br />Avoid breathing gas. Use only outdoors or in a well -ventilated area. Avoid contact with eyes, skin, <br />and clothing. Wash hands thoroughly after handling. Avoid release to the environment. Observe <br />good industrial hygiene practices. Wear appropriate personal protective equipment. Use personal <br />protection as recommended in Section 8 of the SDS. <br />Conditions for safe storage, Store locked up. Store in a cool, dry place out of direct sunlight. Store in original tightly closed <br />including any incompatibilities container. Store in a well -ventilated place. Store in cool place. Refrigeration recommended. Do not <br />store near combustible materials. Keep away from food, drink and animal feedingstuffs. Store <br />away from incompatible materials (see Section 10 of the SDS). Store in accordance with NFPA <br />430 requirements for Class II oxidizers. <br />8. Exposure controls/personal protection <br />Occupational exposure limits <br />US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000) <br />Components Type Value <br />Chlorine (CAS 7782-50-5) <br />Ceiling <br />3 mg/m3 <br />1 ppm <br />US. ACGIH Threshold Limit Values <br />Components <br />Type <br />Value <br />Chlorine (CAS 7782-50-5) <br />STEL <br />0.4 ppm <br />TWA <br />0.1 ppm <br />Chlorine - Chlorine Liquefied Gas Under Pressure SDS US <br />921762 Version #: 02 Revision date: 05/20/2020 Issue date: 05-August-2014 3/8 <br />