My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
317 West Washington Street_BLUEPRINT Central High School New Education Vol II
sbend
>
Public
>
Historic Preservation
>
Temporary
>
Central High BLUEPRINTS
>
317 West Washington Street_BLUEPRINT Central High School New Education Vol II
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2021 2:04:34 PM
Creation date
2/19/2021 3:04:54 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
317 West Washington Street
HPC Document Type
Blueprint
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRST FLOOR - NORTH KEYNOTES <br />POWER PLAN GENERAL NOTES - TYPICAL ALL FLOORS <br />J <br />�! It tl 11 <br />f__ <br />l ZO NE6 <br />11611 <br />ZONE6 <br />11,13,15 <br />LV I -I <br />LV-1 <br />ZONE 5 <br />To 4Cf <br />LV la,I4 <br />ZONE 6 <br />• <br />ZONE6 <br />LV24,26 <br />`.'.. �•.�`:°�b:2?�"i¢.�w�n::k 'f: �:u•..{u:TiiV�i&:'..v'v.i6:.Y:<`�: <br />ZONE6 <br />ZONE 9, <br />►p F <br />ZONE 6 <br />(I)ZONE6 <br />_ZONE 6 <br />CABINET HEATER. 1/30 HP 115V. <br />TERMINAL UNIT. 1/3 HP 277V. 1.8 FLA. <br />TERMINAL UNIT. (2) 1/2 HP 277V. 7.0 FLA. PROVIDE <br />DUCT MTD. SMOKE DETECTOR ON SUPPLY DUCTWORK. WIRE <br />DETECTOR TO NEAREST DETECTOR ZONE AND WIRE INTO TERMINAL <br />UNIT STARTER CONTROL CIRCUIT. <br />TERMINAL <br />TERMINAL <br />TERMINAL <br />TERMINAL <br />UNIT. <br />UNIT. <br />UNIT. <br />UNIT. <br />1/8 HP 277V. 1.0 FLA. <br />1/2 HP 277V. 3.1 FLA. <br />1/15 HP 277V. 0.6 FLA. <br />(*2) 1/3 HP 277V. 4.05 FLA. <br />THRU-FLOOR COMBINATION SERVICE PEDESTAL WITH ONE 7/8" <br />DIA. OPENING FOR FLEXIBLE CONDUIT AND ONE INSULATED <br />BUSHING. <br />3/4"C TO CABLE TRAY. <br />CABLE TRAY ABOVE CEILING. <br />GFI RECEP MTD. HORIZONTALLY IN BACKSPLASH. ARRANGE <br />WIRING TO PROTECT DOWNSTREAM RECEPS. <br />STUB CABLE TRAY INTO EXISTING VERTICAL CHASE FOR ACCESS <br />TO SECOND FLOOR. <br />STUB CABLE TRAY INTO EXISTING VERTICAL CHASE FOR ACCESS <br />TO GROUND FLOOR. <br />EXTEND 120V SERVICE TO J-BOX IN "VIEW-LITE". MOUNT, <br />+ 33" AFF. <br />EXTEND 120V SERVICE TO J-BOX IN DRYER. <br />MOUNT SIX (6) DUPLEX RECEPS + 44" AFF. <br />MOUNT GFI OUTLETS ABOVE SINK AND BELOW SHELF. <br />TWO (2) 8 FT. SECTIONS OF PLUGMOLD STRIP WITH OUTLET <br />2'-0" 0.C. MOUNTED + 44" AFF. <br />REFER TO DRAWING E1.3 FOR DETAIL. <br />EF3. 1/6 HP 115V. PROVIDE MAN. FRACT. HP MOTOR <br />STARTER. CONTROLLED BY ENERGY MANAGEMENT SYSTEM. <br />OUTLET BOX FOR FUTURE MICROPHONE JACK. LOOP 3/4"C <br />BETWEEN BOXES, THEN 3/4"C HOMERUN BACK TO J-BOX IN <br />CONTROL AREA. <br />BACKBOX FOR FUTURE SPEAKER. EXTEND 3/4"C HOMERUN BACK <br />TO J-BOK IN CONTROL AREA. <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />�LV2 <br />141 <br />3 <br />KEY PLAN <br />THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING <br />AND PATCHING REQUIRED FOR ELECTRICAL WORK, INCLUDING <br />OPENINGS REQUIRED FOR NEW CONSTRUCTION, AS WELL AS THOSE <br />OPENINGS/VOIDS CREATED BY THE REMOVAL OF EXISTING CON- <br />DUITS, BOXES, PANELBOARDS, ETC. REFER TO SPECIFICATION <br />SECTIONS 01045 - CUTTING AND PATCHING AND SECTION 09200 <br />- LATH AND PLASTER. <br />2 WHERE NEW WORK IS INDICATED ON EXISTING WALLS IN <br />FINISHED SPACES, IT IS INTENDED THAT THE WALL BE <br />CHANNELED FOR THE WORK. THIS INCLUDES, BUT IS NOT <br />LIMITED TO, CONVENIENCE OUTLETS, TELEPHONE/COMPUTER <br />OUTLETS, FIRE ALARM DEVICES, ETC. <br />3 STUB A 3/4" CONDUIT FROM EACH TELEPHONE/COMPUTER WALL <br />OUTLET AND TURN OUT OF THE WALL ABOVE THE ACCESSIBLE <br />CEILING IN EACH AREA. TYPICAL. <br />4 ALL ISOLATED GROUND RECEP CIRCUITS SHALL INCLUDE BOTH A <br />DEDICATED GROUNDING CONDUCTOR AND DEDICATED NEUTRAL <br />CONDUCTOR. THE NEUTRAL CONDUCTOR SHALL NOT SERVE ANY <br />OTHER CIRCUITS - PROVIDE A SEPARATE NEUTRAL FOR OTHER <br />CIRCUITS IN THE RACEWAY SYSTEM. <br />5 REFER TO REFLECTED CEILING PLANS FOR COORDINATION OF <br />SMOKE DETECTOR LOCATIONS. <br />4 <br />SfYMBOL <br />S <br />S3 <br />S4 <br />SF <br />SD <br />NOTE: <br />C <br />I <br />HH <br />ELECTRICAL SYMBOL LIST <br />DESCRIPTION <br />SWITCH OUTLETS <br />Single pole, flush mounted toggle switch. <br />Mount at 50" AFF, unless noted, to centerline <br />of outlet box. <br />Three way, flush mounted toggle switch. <br />Four way, flush mounted toggle switch. <br />Fan switch (Fractional Starter) <br />Dimmer switch <br />RECEPTACLE OUTLETS <br />"WP" subscription letters noted along side <br />symbol indicate weather proof outlet. <br />"GFI" indicates ground fault interrupter. <br />Flush single receptacle outlet mounted 18" AFF: <br />unless noted, to centerline of outlet box. <br />Flush duplex receptacle outlet mounted 18" AFF, <br />unless noted, to centerline of outlet box. <br />Flush quadruplex receptacle outlet mounted 18" <br />AFF, unless noted, to centerline of outlet box, <br />Duplex receptacle outlet, split wired to two <br />circuits. <br />CIRCUITING <br />Conduit and wiring'. Arrow indicates homerun. <br />Number of strokes indicates number of wires or <br />cables in conduit. <br />LIGHTING <br />Incandescent or H.I.D. lighting fixture. <br />Letter indicates type. <br />Exit light <br />Fluorescent lighting fixture. Letter indicates <br />type. <br />TELEPHONE/COMPUTER SYSTEM <br />Y Telephone/computer outlet. Mount 18" AFF, <br />unless noted, to centerline of outlet box. <br />CP <br />Eql <br />Uv <br />Telephone/computer outlet. Floor mounted. <br />PANELBOARDS, SWITCHBOARDS AND RELATED EQUIPMENT <br />Flush mounted panelboard and cabinet <br />Surface mounted panelboard and cabinet <br />Equipment control panel <br />Externally operated disconnect switch. Fused <br />or non -fused as indicated <br />Combination disconnect switch and magnetic <br />motor starter <br />POWER EQUIPMENT <br />Motor location. <br />Power transformer <br />Circuit breaker <br />Fusible element <br />Single throw 'knife switch <br />Ground <br />Contactor <br />FIRE ALARM SYSTEM <br />Fire alarm pull station <br />Fire alarm audio-visual device <br />Fire alarm smoke detector <br />Fire alarm heat detector <br />THIS PROJECT INCORPORATES A RETURN AIR PLENUM <br />Plumbing and Mechanical°note: no plastic <br />pipe shall be used above finished ceiling. <br />Electrical note: return air rated plenum <br />cable to be used for all low voltage applica- <br />tions. All line voltage wiring to be in an <br />approved raceway. <br />General note: No combustibl4 materials are <br />to be located in the plenum area. Wood may <br />be used if fire treated to meet the required <br />flame and smoke ratings. However, it is <br />recommended that no wood be used. <br />RENOVATION OF <br />CENTRAL HIGH SCHOOL <br />SOUf'H. BID COMMUNITY SCHOOL COBPOBAiIQV <br />FIRST FLOOR PLAN -NORTH <br />POWER P LAN <br />Project No. <br />87264.00 <br />Da to <br />AUGUST 16. 1989 <br />Scale <br />1. /8' »1 I ON <br />Revisions <br />Drawn By <br />808L1XLS ' <br />7d- <br />• <br />• <br />• <br />• <br />• <br />THE GROUP. at. <br />►lsssiq, Design and lbloysniat Sere icon fa the It Environment <br />0 415 Lincolnlq East 116ahssoko, Indiana 41644 ('21Z2 '1076 <br />I 0 352 South Fif th St. Quinn, Indiana 16526 (219)534-3502 <br />Sheet <br />E2.3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.