Laserfiche WebLink
FIRST FLOOR - NORTH KEYNOTES <br />POWER PLAN GENERAL NOTES - TYPICAL ALL FLOORS <br />J <br />�! It tl 11 <br />f__ <br />l ZO NE6 <br />11611 <br />ZONE6 <br />11,13,15 <br />LV I -I <br />LV-1 <br />ZONE 5 <br />To 4Cf <br />LV la,I4 <br />ZONE 6 <br />• <br />ZONE6 <br />LV24,26 <br />`.'.. �•.�`:°�b:2?�"i¢.�w�n::k 'f: �:u•..{u:TiiV�i&:'..v'v.i6:.Y:<`�: <br />ZONE6 <br />ZONE 9, <br />►p F <br />ZONE 6 <br />(I)ZONE6 <br />_ZONE 6 <br />CABINET HEATER. 1/30 HP 115V. <br />TERMINAL UNIT. 1/3 HP 277V. 1.8 FLA. <br />TERMINAL UNIT. (2) 1/2 HP 277V. 7.0 FLA. PROVIDE <br />DUCT MTD. SMOKE DETECTOR ON SUPPLY DUCTWORK. WIRE <br />DETECTOR TO NEAREST DETECTOR ZONE AND WIRE INTO TERMINAL <br />UNIT STARTER CONTROL CIRCUIT. <br />TERMINAL <br />TERMINAL <br />TERMINAL <br />TERMINAL <br />UNIT. <br />UNIT. <br />UNIT. <br />UNIT. <br />1/8 HP 277V. 1.0 FLA. <br />1/2 HP 277V. 3.1 FLA. <br />1/15 HP 277V. 0.6 FLA. <br />(*2) 1/3 HP 277V. 4.05 FLA. <br />THRU-FLOOR COMBINATION SERVICE PEDESTAL WITH ONE 7/8" <br />DIA. OPENING FOR FLEXIBLE CONDUIT AND ONE INSULATED <br />BUSHING. <br />3/4"C TO CABLE TRAY. <br />CABLE TRAY ABOVE CEILING. <br />GFI RECEP MTD. HORIZONTALLY IN BACKSPLASH. ARRANGE <br />WIRING TO PROTECT DOWNSTREAM RECEPS. <br />STUB CABLE TRAY INTO EXISTING VERTICAL CHASE FOR ACCESS <br />TO SECOND FLOOR. <br />STUB CABLE TRAY INTO EXISTING VERTICAL CHASE FOR ACCESS <br />TO GROUND FLOOR. <br />EXTEND 120V SERVICE TO J-BOX IN "VIEW-LITE". MOUNT, <br />+ 33" AFF. <br />EXTEND 120V SERVICE TO J-BOX IN DRYER. <br />MOUNT SIX (6) DUPLEX RECEPS + 44" AFF. <br />MOUNT GFI OUTLETS ABOVE SINK AND BELOW SHELF. <br />TWO (2) 8 FT. SECTIONS OF PLUGMOLD STRIP WITH OUTLET <br />2'-0" 0.C. MOUNTED + 44" AFF. <br />REFER TO DRAWING E1.3 FOR DETAIL. <br />EF3. 1/6 HP 115V. PROVIDE MAN. FRACT. HP MOTOR <br />STARTER. CONTROLLED BY ENERGY MANAGEMENT SYSTEM. <br />OUTLET BOX FOR FUTURE MICROPHONE JACK. LOOP 3/4"C <br />BETWEEN BOXES, THEN 3/4"C HOMERUN BACK TO J-BOX IN <br />CONTROL AREA. <br />BACKBOX FOR FUTURE SPEAKER. EXTEND 3/4"C HOMERUN BACK <br />TO J-BOK IN CONTROL AREA. <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />�LV2 <br />141 <br />3 <br />KEY PLAN <br />THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING <br />AND PATCHING REQUIRED FOR ELECTRICAL WORK, INCLUDING <br />OPENINGS REQUIRED FOR NEW CONSTRUCTION, AS WELL AS THOSE <br />OPENINGS/VOIDS CREATED BY THE REMOVAL OF EXISTING CON- <br />DUITS, BOXES, PANELBOARDS, ETC. REFER TO SPECIFICATION <br />SECTIONS 01045 - CUTTING AND PATCHING AND SECTION 09200 <br />- LATH AND PLASTER. <br />2 WHERE NEW WORK IS INDICATED ON EXISTING WALLS IN <br />FINISHED SPACES, IT IS INTENDED THAT THE WALL BE <br />CHANNELED FOR THE WORK. THIS INCLUDES, BUT IS NOT <br />LIMITED TO, CONVENIENCE OUTLETS, TELEPHONE/COMPUTER <br />OUTLETS, FIRE ALARM DEVICES, ETC. <br />3 STUB A 3/4" CONDUIT FROM EACH TELEPHONE/COMPUTER WALL <br />OUTLET AND TURN OUT OF THE WALL ABOVE THE ACCESSIBLE <br />CEILING IN EACH AREA. TYPICAL. <br />4 ALL ISOLATED GROUND RECEP CIRCUITS SHALL INCLUDE BOTH A <br />DEDICATED GROUNDING CONDUCTOR AND DEDICATED NEUTRAL <br />CONDUCTOR. THE NEUTRAL CONDUCTOR SHALL NOT SERVE ANY <br />OTHER CIRCUITS - PROVIDE A SEPARATE NEUTRAL FOR OTHER <br />CIRCUITS IN THE RACEWAY SYSTEM. <br />5 REFER TO REFLECTED CEILING PLANS FOR COORDINATION OF <br />SMOKE DETECTOR LOCATIONS. <br />4 <br />SfYMBOL <br />S <br />S3 <br />S4 <br />SF <br />SD <br />NOTE: <br />C <br />I <br />HH <br />ELECTRICAL SYMBOL LIST <br />DESCRIPTION <br />SWITCH OUTLETS <br />Single pole, flush mounted toggle switch. <br />Mount at 50" AFF, unless noted, to centerline <br />of outlet box. <br />Three way, flush mounted toggle switch. <br />Four way, flush mounted toggle switch. <br />Fan switch (Fractional Starter) <br />Dimmer switch <br />RECEPTACLE OUTLETS <br />"WP" subscription letters noted along side <br />symbol indicate weather proof outlet. <br />"GFI" indicates ground fault interrupter. <br />Flush single receptacle outlet mounted 18" AFF: <br />unless noted, to centerline of outlet box. <br />Flush duplex receptacle outlet mounted 18" AFF, <br />unless noted, to centerline of outlet box. <br />Flush quadruplex receptacle outlet mounted 18" <br />AFF, unless noted, to centerline of outlet box, <br />Duplex receptacle outlet, split wired to two <br />circuits. <br />CIRCUITING <br />Conduit and wiring'. Arrow indicates homerun. <br />Number of strokes indicates number of wires or <br />cables in conduit. <br />LIGHTING <br />Incandescent or H.I.D. lighting fixture. <br />Letter indicates type. <br />Exit light <br />Fluorescent lighting fixture. Letter indicates <br />type. <br />TELEPHONE/COMPUTER SYSTEM <br />Y Telephone/computer outlet. Mount 18" AFF, <br />unless noted, to centerline of outlet box. <br />CP <br />Eql <br />Uv <br />Telephone/computer outlet. Floor mounted. <br />PANELBOARDS, SWITCHBOARDS AND RELATED EQUIPMENT <br />Flush mounted panelboard and cabinet <br />Surface mounted panelboard and cabinet <br />Equipment control panel <br />Externally operated disconnect switch. Fused <br />or non -fused as indicated <br />Combination disconnect switch and magnetic <br />motor starter <br />POWER EQUIPMENT <br />Motor location. <br />Power transformer <br />Circuit breaker <br />Fusible element <br />Single throw 'knife switch <br />Ground <br />Contactor <br />FIRE ALARM SYSTEM <br />Fire alarm pull station <br />Fire alarm audio-visual device <br />Fire alarm smoke detector <br />Fire alarm heat detector <br />THIS PROJECT INCORPORATES A RETURN AIR PLENUM <br />Plumbing and Mechanical°note: no plastic <br />pipe shall be used above finished ceiling. <br />Electrical note: return air rated plenum <br />cable to be used for all low voltage applica- <br />tions. All line voltage wiring to be in an <br />approved raceway. <br />General note: No combustibl4 materials are <br />to be located in the plenum area. Wood may <br />be used if fire treated to meet the required <br />flame and smoke ratings. However, it is <br />recommended that no wood be used. <br />RENOVATION OF <br />CENTRAL HIGH SCHOOL <br />SOUf'H. BID COMMUNITY SCHOOL COBPOBAiIQV <br />FIRST FLOOR PLAN -NORTH <br />POWER P LAN <br />Project No. <br />87264.00 <br />Da to <br />AUGUST 16. 1989 <br />Scale <br />1. /8' »1 I ON <br />Revisions <br />Drawn By <br />808L1XLS ' <br />7d- <br />• <br />• <br />• <br />• <br />• <br />THE GROUP. at. <br />►lsssiq, Design and lbloysniat Sere icon fa the It Environment <br />0 415 Lincolnlq East 116ahssoko, Indiana 41644 ('21Z2 '1076 <br />I 0 352 South Fif th St. Quinn, Indiana 16526 (219)534-3502 <br />Sheet <br />E2.3 <br />