Laserfiche WebLink
toilet facilities therein, and to connect such facilities directly <br /> with the proper public sewer in accordance with the provisions of <br /> this ordinance, within ninety ( 90) days after date of official <br /> notice to do so, provided that said public sewer is within three <br /> hundred ( 300) feet of the property line. <br /> Section 17-10 . Pretreatment of Industrial Wastes. <br /> Pretreatment of industrial wastes from major contributing <br /> industries prior to discharge to the treatment works is required <br /> and is subject to the Rules and Regulations adopted by the EPA ( 40 <br /> C.F.R. Part 403) , and "Guidelines Establishing Test Procedures for <br /> Analysis of Pollutants" ( 40 C.F.R. Part 136) , in addition to any <br /> more stringent requirements established by the City and subsequent <br /> State or Federal Guidelines and Rules and Regulations. <br /> (a) Limitations on wastewater strength: <br /> (1) National Categorical Pretreatment Standards as <br /> promulgated by the (EPA) shall be met by all affected <br /> nonresidential waste dischargers. An application for modification <br /> of the National Categorical Pretreatment Standards may be <br /> considered by the Board of Public Works when the wastewater <br /> treatment plant achieves consistent removal of the pollutants <br /> described herein. <br /> (2) State and local requirements and limitations on <br /> discharges shall be met by all dischargers when such requirements <br /> and limitations are more stringent than federal requirements and <br /> limitations. <br /> ( 3 ) No discharger shall use potable water to dilute a <br /> discharge as a substitute for adequate treatment of prohibited <br /> substances to achieve compliance with the standards set forth in <br /> this division. <br /> (4) Under no circumstances shall a discharger release water <br /> or waste containing concentrations of the following substances in <br /> amounts exceeding the stated values: <br /> Parameter 1-Day-Maximum 4-Day Average <br /> Arsenic 1. 0 0.2 <br /> Cadmium 2.7 1. 2 <br /> Copper 5. 0 3 . 5 <br /> Cyanide 1. 5 0. 5 <br /> Lead 2. 0 0. 8 <br /> Mercury 0. 1 0.005 <br /> Nickel 5. 0 2.5 <br /> Total Chromium 7. 5 5.0 <br /> Zinc 10. 0 6.0 <br /> all units mg/l. <br /> (b) Accidental discharges: <br /> (1) A discharger shall provide a plan of protection from <br /> accidental discharge of prohibited or regulated substances listed <br /> herein. Each protection plan is subject to the approval of the <br /> Board of Public Works. <br /> ( 2) Dischargers shall notify the Director immediately upon <br /> the occurrence of a "slug" or accidental discharge of substances <br /> prohibited by this division. The notification shall include <br /> 1nr_ation of dischar_ae_ date and time of occurrence. tube of waste. <br />