Filled in by W A Jones <br />The existing hydraulics (wet kits) shall be removed from the prime movers and new <br />hydraulics tanks capable of both operating the new Anti-ice system and using system to <br />Operate Cities existing drop deck low boy trailers shall be installed on them. <br />H draulic tank shall be a minimum of a 40 gallonYRright located behind the cab. <br />Existing pto's shall be removed and new pto's to fit prime mover transmissions shall be <br />provided and installed. The newpto's shall be hot shift with wefts line flange. <br />New load sense pumps shall be provided and installed. Pumps shall be of proper rpm and size <br />tooperate ant-ice and drop deck units. <br />See Rc°. <br />®Yes ❑No <br />❑Yes ®No <br />❑Yes DNo <br />Controllers: To maintain consisting through-out the City's flect, the anti-ice controller shall be <br />Certified Power Freedom 2.1 controller. <br />❑Yes [:]No <br />Valves there shall be two valve sections provided and installed in a weather tight enclosure. <br />One valve section shall operate the low body drop deck trailer and the second valve section <br />shall be proportional to operate the anti-ice system. There shall be an on off valve to allow <br />the operator to switch between the low boy valve and the anti- ice valve. <br />Additional item: There shall be four (4) additional cartridges provided Iooseupon delivery <br />of the unit, Cartridges shall be able to fit the City's newest dump plow truck's central <br />hydraulic systems. This will allow the City to if needed to utilize their plow truck to operate <br />anti-ice system. It will be the bidder's responsibility to ensure that the loose cartridges fit the <br />City's existing central hydraulic system that is in their plow units. <br />Hoses & fittings: Bidder shall provide and install any hoses and fittings, quick connectors to <br />insure proper function from the prime mover to the trailer and the anti-ice unit for proper <br />uca0,P <br />OYes ONo <br />[AYes [:]No <br />©Yes DNo <br />PLEASE NOTE: After Inspection of the units the prime movers the City originally planed on pulling the anti -ice units <br />planed to use, will not function in a correct manner for this application as the tractors are manual transmissions should <br />be automatic. If the City would want to use thier existing tandem or single axle plow trucks for this application than all material and <br />cost functions are included. <br />W. A Jones is showing option (A) as pumps, wet kits etc in case the City desires to use the Anti -ice tanks with Automatic <br />transmissions tractors as thier prime mover. <br />W A Jones is also showing a additional option (B) for Slip In Anti Ice units of 1800 gallons. These units would sit in back of <br />the City's existing plow trucks for Anti -ice applications <br />Option A) Pto's, pumps wet tanks, valves to allow a Tractor with an automatic transmission to function as it should for a prime mover <br />in Anti -Ice applications, add $15,927,00 per unit for two units add $31,854.00 <br />Option 13)1800 gallon slip in Anti -Ice units with complete platforms with leg kits, lights, valves, etc for complete functioning unit <br />unit per INDOT specifications $39,773.00 <br />11 <br />