Laserfiche WebLink
24.5 PORTABLE/ ONBOARD SUCTION AND ASPIRATION SYSTEM <br />A portable/onboard, complete self-contained S-SCORT VX-2 dual mode unit with <br />battery charger shall be installed on the primary action area wall. It shall include a <br />charging retention bracket hard -wired to 12 VDC power. A 1,200-cc suction canister, <br />6' suction tubing, and suction tip shall be supplied with unit. <br />Y X N <br />24.6 SHARPS/BIO-HAZARD <br />A sharps container with a crash stable mounting bracket shall be supplied and <br />shipped loose. A biohazard container with lid and twelve [12] red biohazard bags <br />shall be shipped loose for installation by the department. <br />Y X N <br />24.7 PATIENT CODE SIGNAL SYSTEM <br />In the action area switch console, there shall be three [3] colored switches (red, <br />yellow and green) that activate corresponding indicator lights in the driver's switch <br />console. In addition, there shall be a switch in the action area switch console that <br />activates a buzzer in the driver's compartment. These lights and buzzer shall be <br />used to notify the driver of any change in the patient's status. <br />Y X N <br />24.8 RADIO WIRING <br />Radio wiring as follows: <br />1. 10-gauge A+ to console with ignition. <br />2. 8-gauge A+ and A- to console in cab, hot. <br />3. 8-gauge A+ and A- to radio compartment in box, hot. <br />4. Three (3) antenna accesses will be provided inside box: front -center, middle - <br />center, and rear -center. <br />5. Two (2) RG-58 cables installed at rear -center and middle -center access <br />points with NMO-style antenna mounts. Both will be run to radio <br />compartment. Antenna cables will have 18" excess at both ends. <br />6. Wiring for the intercom system for cab and patient compartment to be <br />determined at the pre -build meeting. Department will supply components of <br />intercom system. 10 conductor strobe cables shall be run from center console <br />to action area and from action area to radio housing at end of squad bench. <br />Y X N <br />24.9 FIRE EXTINGUISHERS <br />Two (2) 5-pound rated ABC fire extinguishers with mounting brackets shall be <br />furnished with the ambulance. These shall be shipped loose to allow the department <br />to install in the desired locations. <br />Y_X_N <br />24.9.1 Two (2) Two (2) Streamlight, model #SL-20-X handheld flashlights, each with <br />charger base, shall be provided. Mounting location shall be one (1) on the driver <br />side front console located directly behind the gear shift selector and one (1) located <br />in the rearward ALS health center located halfway up. <br />Y_X_N <br />25.0 MODULE SURFACE PREPARATION <br />