Laserfiche WebLink
size oxygen bottle. Cast brackets will be used to house customer's bottles. <br />Y_X_N <br />22.9 SQUAD BENCH CABINET <br />A cabinet shall be located over the squad bench at the ceiling level, rearward of the <br />entry/egress door opening. This cabinet shall be divided into three (3) separate <br />sections. The cabinet shall be finished in the same material as the rest of the interior <br />cabinets. This cabinet shall be compliant with the KKK 1822 revision F specification. <br />Y_X_N_ _ <br />22.9.1 There shall be three (3) 3/8" flip -up Plexiglas doors. <br />Y_X_N_ _ <br />22.9.2 A stainless Steel Round Southco latch (or equal) shall be provided on each <br />door. <br />Y_X_N_ <br />23.0 IV HOLDERS <br />Four [4] ceiling mounted Cast Products 2008-1 recessed IV holders shall be <br />supplied. These shall be located at the head and foot areas, two [2] over the squad <br />bench and two [2] over the primary cot. They shall have a rubber, foldaway storage <br />when not in use. Each holder must have the capacity to hold two [2] bottles and <br />have Velcro securing straps. <br />Y_X_N <br />23.1 COT MOUNT <br />A Stryker Power Load cot mount shall be supplied. It must accommodate the Stryker <br />Power Pro XT. <br />Y_X_N <br />The cot mount shall be located in the center of the patient compartment. <br />Y_X_N <br />23.2 ASSIST RAILS <br />One [1] 90" long, 1.50" diameter, smooth satin finished overhead grab rail shall be <br />provided and securely fastened to the ceiling over the primary cot. One [1] 60" long, <br />1.50" diameter, smooth satin finished overhead grab rail shall be provided and <br />securely fastened over the squad bench. The grab rails shall be fastened with bolts, <br />washers and nuts of the appropriate dimension, through the interior ceiling panel and <br />through the .090" aluminum accessory plate welded into the roof structure. Assist <br />rails fastened with self -tapping machine screws are not acceptable. These grab rails <br />must meet or exceed AMD Standard 008, Load Test for Ambulance Patient <br />Compartment Grab Rail. <br />Y_X_N <br />23.3 SIGN <br />Two self-adhesive "NO SMOKING OXYGEN EQUIPPED" and "FASTEN <br />SEATBELT" sign (1) shall be installed in the 1st action area. <br />Y_X_N_ <br />24.0 OXYGEN <br />The medical oxygen system shall be capable of storing and supplying a minimum of <br />3000 liters of oxygen. A suitable high-pressure hose shall be provided. The <br />concealed oxygen supply hose shall be .250" ID, .50" OD nylon base with polyester <br />