11/09/2020 Page 15 <br />PART NO S DESCRIPTION QTY <br />06-RR-1809 |-- Patient Area Radio : None 1 <br />06-RR-1900 S < |-- Intercom, Pre-wire ONLY 1 <br />(2) 22-GAUGE 9 WIRE CABLE INSTALLED FROM THE FORWARD AREA OF THE <br />OVERHEAD SQUAD BENCH CABINET TO THE CENTER CONSOLE <br />06-SO-0000 125V SHORE LINE AND OUTLETS 1 <br />06-SO-0500 |-- Shore Line Inlet: 20A Super Auto Eject, ILOS 1 <br />06-SO-00L1 |-- Inlet location: Aft of Left Front compartment 1 <br />06-SO-1005 |-- Cover, Yellow, Shore Line Inlet : 20A Super Auto Eject, STD 1 <br />06-SO-10TT < |-- Inpower Timer: VCM-05-01SF, Installed 1NOTE: This allows the auto eject to be wired to the ignition switch In lieu of splicing into theOEM starter circuit and is required any this vehicle <br />06-SO-1400 |-- **125 Volt OUTLETS**1 <br />06-SO-1401 < <br /> |-- 125 VAC Outlet, No 1: 15A, Hospital Grade, IVORY 1 <br />All 125 VAC outlets shall be back lighted when power is applied to the outlet. <br />06-SO-14L1 |-- LOCATION: Action Area, standard location 1 <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1402 |-- 125 VAC Outlet, No 2: 15A, Hospital Grade, IVORY 106-SO-14L3 |-- LOCATION: RF ALS, (See Drawing)106-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1403 |-- 125 VAC Outlet, No 3: 15A, Hospital Grade, IVORY 1 <br />06-SO-14L4 |-- LOCATION: Telemetry Area, (See Drawing)1 <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1404 |-- 125 VAC Outlet, No 4: 15A, Hospital Grade, IVORY 1 <br />06-SO-14L2 |-- LOCATION: Curbside, see Drawing 1 <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1405 |-- 125 VAC Outlet, No 5: 15A, Hospital Grade, IVORY 1 <br />06-SO-14L3 < |-- LOCATION: RF ALS, (See Drawing)1 <br />LOWER SECTION <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 106-SO-1100 **INTERIOR 12 Volt OUTLETS**1 <br />06-SO-10XZ |-- 12 Volt outlets two separate single outlets 1 <br />06-SO-10Y0 |-- 12V Outlet, No 1: Power Point Single - Wire thru Med Isolator 1 <br />06-SO-11L1 |-- LOCATION: Action Area, standard location 1 <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1910 |-- Power Source: Medical Isolator , Batt Sw Hot 1 <br />06-SO-1102 |-- 12V Outlet, No 2: Power Point - Wire thru Med Isolator 1 <br />06-SO-11L3 |-- LOCATION: RF ALS, (See Drawing)1 <br />06-SO-14O2 |-- Outlet mounting ORIENTATION: Vertical 1 <br />06-SO-1913 |-- Power Source: The SAME as outlet No 1 1 <br />06-SO-1127 S < |-- Hard Wired 12V Circuit, For Customer/Dealer Supplied Component 1 <br />FOR KNOX MED VAULT <br />06-EC-1410 S |-- Location: Cabinet O1 1 <br />06-SO-1912 |-- Power Source: Medical Isolator , Battery (CONSTANT) Hot 1 <br />06-SS-01B0 Siren: Federal PA-300-012MSC, ILOS, 43/4400LP 1 <br />06-SS-DF11 |-- Siren Speakers: Federal # ES100-ESMFT-EF, Navistar MV 607 1 <br />06-SS-SW01 < |-- Siren / Horn Switch: In Cab Console 1 <br />Siren Functions OR OEM Horn <br />06-SS-SW04 |-- microphone clip not installed Tie to Siren Microphone cord.1 <br />06-SS-1900 Air Horn System: GROVER -med duty 1 <br />06-SS-1800 S < |-- Air Horns, ACTIVATION Valve: Manual Valve w/ Lanyard IAT 1Constant hot, CANNOT be hooked up with door switches or primary/secondary <br />06-SS-1901 S< |-- Air Horns ACTIVATION: Foot Switch / Solenoid Valve No 1126 1 <br />Installed on Driver Side