Laserfiche WebLink
NFPA Amp Load CalculatorV2A10/14/1997 <br />CITY:South Bend Fire Department <br />SHEDAMPS USED NFPA TOTAL AMPS SHED TOTAL <br />QTY1 IF NOITEMGROSSMAXMINMAXMINMAXMIN <br />1AC- 45,000 BTU W/Heater- Split Condenser484848004848 <br />11Alarm- Back-up Electronic0.80000 <br />11Brake Jacobs Cummins3.70000 <br />11Custom Chassis +engine +transmission242411241100 <br />11Engine- Cummins 3333300 <br />11Governor- Pressure0.50.50.50.50.500 <br />1Heater- Auxiliary 30,000 BTU (2 fan)6.66.66.6006.66.6 <br />1Arrow Stick Light LED (intermittent Load)40000 <br />161Light- 7" Dome LED Compartment (each)0.90.90.97.27.2 <br />21Light- Chassis- BackUp2.12.14.2000 <br />1Light- Chassis- Engine Maintenance0.60.60.6000.60.6 <br />11Light- Chassis- License0.590.590.590.590.5900 <br />71Light- Chassis- Marker- LED (7 on body standard)0.140.140.140.980.9800 <br />61Light- Ground (each light) 6 Standard2.12.12.112.612.600 <br />11Light- OK to Pump0.20.20.20.20.200 <br />11Light- Open Compartment- Flashing2.12.12.12.12.100 <br />121Light- Package- Lower Federal LED's (each)0.90.90.910.810.800 <br />11Light- Package- Upper Federal Ltbar LED121212121200 <br />61Light- Package- Upper Federal Quadraflare LED (each)1.51.51.59900 <br />51Light- Panel (each light) 2/Side + 4 top control1.441.441.447.27.200 <br />41Light- Scene (each)7.87.87.8 <br />21Light- Step- Flush0.330.330.330.660.6600 <br />21Light- Step- Hooded0.60.60.61.21.200 <br />1Mirror- West Coast- Heated & Lighted6660066 <br />11Pump- Gauge Package5555500 <br />11Radio (default)5555500 <br />11Siren- Q2B1000000 <br />11Siren- Whelen 295- 100 watt999000 <br />11Trans- Allison EVS30009929200 <br />11Trans- Temp Light & Buzzer0.10000 <br />1Windshield Wiper550050 <br />TOTAL124.2391.0366.261.2 <br />NOTE: No value in a row indicates an intermittent load <br />and is not used in calculating total loads <br />Maximum amp load190.43(includes shed item) <br />Minimum amp load91.03 <br />MAX= Maximum Continuous Load <br />MIN= Minimum NFPA Load Requirements <br />AMPS <br />Note: Check availabilityRatedIdleMAXMIN <br />1Alternator- 360360320360320 <br />00 <br />(Positive number indicates power reserve)ALTERNATOR RESERVE235.77228.97 <br />SHEDABLE AMPS66.2061.20 <br />(Negative number indicates power reserve)AMPS TO SHED-169.57-167.77 <br />Adequate alternator at idleYES <br />Load management requiredNO <br />(Positive number indicates power reserve)ALTERNATOR RESERVE898.09533.43 <br />SHEDABLE AMPS66.2061.20 <br />(Negative number indicates power reserve)AMPS TO SHED-831.89-472.23 <br />Adequate alternator at idleYES <br />Load management requiredNO <br /> <br />