Laserfiche WebLink
equipped witha 6"(152 mm)retro-reflective whiteband nomore than4" (152mm)fromthe <br />topof the cone, and an additional4"(102 mm)retro-reflective white band 2"(51mm) below <br />the6"(152mm) band. <br />- Five (5)illuminated warning devices such ashighway flares, unless thefive(5)fluorescent <br />orangetraffic coneshaveilluminatingcapabilities. <br />- One automatic externaldefibrillator (AED). <br />-If the supplyhosecarrieddoes not use sexlesscouplings, anadditional doublefemale <br />adapterand doublemale adapter,sized tofitthesupply hose carried, shall becarried <br />mountedinbrackets fastened totheapparatus. <br />-If none ofthepump intakes are valved, a hoseappliancethatisequippedwithone ormore <br />gated intakes withfemaleswivelconnection(s) compatible with the supplyhoseused on one <br />sideanda swivelconnection withpump intake threadson theotherside shall be carried. Any <br />intakeconnectionlargerthan 3 in.(75 mm)shallinclude a pressurereliefdevicethatmeets <br />therequirements of 16.6.6. <br />-If the apparatusdoes not have a 2½" National Hose (NH) intake,an adapterfrom 2½" NH <br />female toa pumpintakeshallbecarried,mountedina bracketfastenedtothe apparatusif <br />notalreadymounted directly totheintake. <br />-If the supplyhosecarriedhasother than 2½" National Hose(NH)threads,adaptersshallbe <br />carried toallowfeedingthe supply hosefrom a 2½"NH threadmaledischarge and to allow <br />the hoseto connectto a 2½" NH femaleintake,mounted in bracketsfastened to the <br />apparatusif notalreadymounteddirectly tothedischarge orintake. <br />SOFT SUCTIONHOSE,PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009edition,section5.7.2requires a minimumof 20ftofsuctionhose or15ft <br />of supplyhose. <br />Hoseis not on theapparatus asmanufactured.Thefiredepartment shall provide suction or <br />supply hose. <br />DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009edition,section5.8.3requires one(1) approved dry chemicalportablefire <br />extinguisher with a minimum 80-B:Cratingmounted in a bracketfastened totheapparatus. <br />The extinguisherisnotonthe apparatusasmanufactured. Thefiredepartment shallprovide <br />andmount the extinguisher. <br />WATER EXTINGUISHER PROVIDED BY FIREDEPARTMENT <br />NFPA 1901, 2009edition,section5.8.3requires one(1) 2.5 gallonorlarger water <br />extinguishermountedin a bracketfastenedto the apparatus. <br />The extinguisherisnotonthe apparatusasmanufactured. Thefiredepartment shallprovide <br />andmount the extinguisher. <br />AXE, FLATHEAD, PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009edition,Section 5.8.3requires one (1)flathead axemounted ina bracket <br />fastened tothe apparatus. <br />The axeisnoton the apparatusasmanufactured.Thefiredepartmentshallprovide and <br />PDF created with pdfFactory Pro trial version www.pdffactory.com <br /> <br />