® <br />PIERCE MANUFACTURING INC. <br />® <br />AN OSHKOSH TRUCK CORPORATION COMPANY <br />Certification Document CD0130 <br />®TM <br />Saber FR - Enforcer <br />Cab Integrity Certification <br />®TM <br />Pierce Manufacturing certifies the integrity of the Saber FR – Enforcercab relative to <br />occupant protection. <br />®TM <br />A specimen representing the substantial structural configuration of the Saber FR – Enforcer <br />cab models has been successfully tested in accordance with the following standards. <br /> SAE J2422 Cab Roof Strength Evaluation – Quasi-Static Loading Heavy Trucks. <br /> European Occupant Protection Standard ECE Regulation No. 29. <br /> SAE J2420 COE Frontal Strength Evaluation – Dynamic Loading Heavy Trucks. <br />Side Impact: The test cab was subjected to dynamic preload <br />where a 14,253 lb moving barrier was slammed into the side of <br />the cab at 5.25 mph, striking with an impact of 13,000 ft-lbs of <br />energy. This test is not required to meet the ECE 29 standard, <br />but is part of the SAE J2422 test procedure and more closely <br />represents the forces a cab will see in a roll-over incident. <br />Frontal Impact: The test cab was struck by the 14,253 lb moving <br />barrier at a speed sufficient to impart the required 32,549 ft-lbs of <br />energy. <br />CD0130 Cab Integrity Certification - Saber FR - Enforcer .doc 1 11/17/2014 <br /> <br />