My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
June 2016
sbend
>
Public
>
Historic Preservation
>
Meeting Minutes and Recordings
>
HPC Meeting Minutes 2016
>
June 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:16:20 PM
Creation date
6/8/2020 10:17:27 AM
Metadata
Fields
Template:
South Bend HPC
HPC Document Type
Minutes
BOLT Control Number
1001364
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
145
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Original exterior building materials in the district include brick, stucco, clapboard, wood shingles, and <br />brick or stone masonry. In some instances, vinyl, composite and aluminum siding have been applied over <br />the original material. <br />Required <br />Original exterior building materials shall be retained when possible. Deterioration of wood materials shall <br />be prevented through repair, cleaning and painting. The existing architectural detail around windows, <br />porches, doors and eaves shall be retained or replaced by replicas of the same design when deteriorated <br />beyond repair. Masonry, including brick and stucco structures, shall be maintained, and properly cleaned <br />only when necessary to halt deterioration or to remove stains and shall be done in a method acceptable for <br />the preservation of the surface: i.e. low-pressure water and soft natural bristle brushes. Brick or masonry <br />mortar joints should be repointed only when there is evidence of moisture problems, or when sufficient <br />mortar is missing to allow water to stand in the mortar joint. Existing mortar shall be duplicated in <br />composition, color, texture, joint size, method of application and joint profile. When repairing stucco, <br />stucco mixture shall be used. A professional shall make a study of the old stucco, to determine the exact <br />mixture and underlayment used in the original work. Some repair methods are not compatible with the <br />original techniques and may cause early disintegration of the repair work and the original work. Ample <br />ventilation must be afforded the structure when siding is installed, in order to prevent increased <br />deterioration of the structure from moisture and insects. <br />Recommended <br />Whenever possible, the original building materials should be restored. When maintaining or repairing <br />original siding is not feasible, aluminum, vinyl or composite siding may be used. When used over wood <br />surfaces, this siding should be the same size and style as the original wood. Every effort should be made <br />to retain the original trim around windows, doors, cornices, gables, eaves and other architectural features. <br />Property owners should contact the Historic Preservation Commission of South Bend and St. Joseph <br />County prior to initiating any restoration or rehabilitation effort. [Address and contact information is <br />listed in the front of the Guidebook.] The Commission is an invaluable source of information about all <br />facets of rehabilitation and restoration — materials, methods, contractors and the like. <br />Prohibited <br />Wood siding shall not be resurfaced with new material that is inappropriate or was unavailable when the <br />building was constructed, such as artificial stone, brick veneer, asbestos or asphalt shingles. Sandblasting <br />or the use of harsh detergents shall not be used on masonry including brick, stucco, limestone, flagstone <br />and sandstone. This method of cleaning erodes the surface material and accelerates deterioration. <br />Repointing shall not be done with a mortar of high Portland cement content which can often create a bond <br />that is stronger than the building material. Usage of Portland cement can cause deterioration as a result of <br />the differing coefficient of expansion and porosity of the historic masonry unit and the mortar. This most <br />often results in serious damage to adjacent brick. Unpainted masonry surfaces shall not be painted unless <br />they had been painted originally. Paint shall not be removed from masonry surfaces by any means that <br />damage the surface. <br />Not Recommended <br />Waterproof or water repellent coatings or surface consolidation treatments should not be used on masonry <br />surfaces unless required to solve a specific problem that has been studied and identified. Coatings are <br />frequently unnecessary and expensive, and can accelerate deterioration of the masonry. Mortar joints, <br />which do not need repointing, should not be repointed. Wood siding should not be power -washed. <br />STAFF RECOMMENDATION: Staff recommends approval. <br />Deb Parcell <br />Deputy Director <br />
The URL can be used to link to this page
Your browser does not support the video tag.