Laserfiche WebLink
vo� <br />A?rush Namt in Atlicatimr S �9'l6�" <br />IN -Vent" Installation Instructions <br />Cor -A Vent, Inc. on -the -roof Intake vent — Let's Fresh Air in when Soffits are Out® <br />Step 1 <br />Begin by cutting a 1 -inch wide slot or a series of 1 -inch diameter holes into the roof deck, 36 <br />inches up from the drip edge. Do not cut the slotiholes any closer than 12 inches from the <br />ends of the roof. Do not cut the slottholes any closer than 36 inches from any valley or 24 <br />inches from any wall. Set saw blade depth accordingly to avoid damaging rafters or trusses. <br />Ste[) 2 <br />Install felt paper or ice & water shield on the roof as <br />normal, but stopping at the slotiholes. Install shingles <br />as normal up to slotiholes, trimming as needed to <br />avoid covering the slot/holes. <br />Lets fros6 air to 0600 soffftsors out <br />Ste[) 3 <br />Snap a chalk line 3 inches down from the bottom of the slotiholes. About 1 inch up from the <br />chalk line, run a minimum''/." bead of flexible caulking. (Note: This bead of caulking will seal <br />the IN -Vent to the roof — depending on the type of shingles, a wider bead may be needed to <br />avoid gaps under the IN -Vent) <br />Step 4 <br />Starting at the chalk line, run a single 12" long bead of flexible caulk 3" <br />in from and parallel to the gable end of the roof or where the end of the <br />vent will be. Start at one end of the roof and tightly wrap the provided <br />12" x 12" IN -Vent End Cap section over the end of the first piece of IN - <br />Vent (see photo at right). Set the vent and End Cap material in the 12" <br />bead of caulk. Install the End Cap section smooth side out' and align <br />the edge'of the End Cap section with the top edge of the IN Vent". <br />Using the chalk line as your gauge, align the bottom edge of the IN- <br />Vent on the chalk line and, with the 2 W roofing nails provided, nail <br />down the vent every 12 inches, using the staples in the IN -Vent as your nail line. Also nail the <br />top edge of the IN -Vent every 12 inches (roofing nail must be long enough to penetrate the <br />roof deck). Install IN -Vent pieces continuously the. length of the roof and use another -End Cap <br />section to close the opposite end. IN -Vent pieces should be installed at least 6 inches past the <br />ends of the slot. <br />Ste[) 5 <br />Install a piece of felt paper or ice & water shield over the top of the IN - <br />Vent, up onto the roof. Apply shingle starter strip to the edge of the IN - <br />Vent and continue installing shingles over the rest of the roof. <br />* - IN Vent End Cap sections feature a V -inhibitor coating on the <br />smooth (shiny) side. Be sure to install these sections properly for <br />Protection from harmful UV degradation. <br />** - If extra End Cap sections are needed, cut 12x12 pieces in half. <br />