My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
November 2011
sbend
>
Public
>
Historic Preservation
>
Meeting Minutes
>
HPC Meeting Minutes 2011
>
November 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:16:19 PM
Creation date
6/8/2020 10:15:17 AM
Metadata
Fields
Template:
South Bend HPC
HPC Document Type
Minutes
BOLT Control Number
1001362
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Froc City of South Bend To:82359578 10/26/2011 11:52 #478 P.0041004 <br />1200 CouNrr-CnY BLUDING <br />227 W JF rvwN BouLwAm <br />Souni Ev o, INDIANA 46601-1830 <br />No4 574/ 235-9371 <br />FAX 574/235-9021 <br />TDD 5741235-5567 <br />CITY of SOUTH BEND STEPHEN J. LUE.CKE, MAYOR <br />COMMUNITY & EcONOMIc DEW-LOPMENT <br />,JEFFREY V. GIBNEY <br />LxEctrrtvE DiREEcroR <br />Property Address: 424 LaMpute Tcnm <br />Property Owners: Porte 234-2095(h) 344-92400 <br />Date: BugW 1, 2011 <br />Inspector: Tag otrne <br />Program: JL.,ttt a Revak& 1Mvrovement Logr <br />Bid Specifications <br />Roof <br />1 Tear -off all roof coverings down to bare wood deck on all surfaces. Replace or repair all <br />deteriorated framing members and sheeting. On all areas install 7/16" OSB sheathing over decking to provide <br />level and adequate nailing surface for new roofing, then with new " NIUM-UDL" Sv_ nthetic Roof <br />Undedayment or approved equal, premium (1-1/2") metal drip edge along all roof edges, appropriate pipe <br />boots and Owens Corning or Cora -Vent brand corrugated vinyl roof ridge vent for proper attic ventilation, <br />needed transition flashing, step and counter flashing at vertical transitions. Install Ice & Water shield along <br />roof eaves and in valleys. Install 235-240 lb. Oakridge dimensional, or GAF Timberline dimensional or <br />approved equal on all pitched roof surfaces a one ply EPDM rubberized roof system or,an approved equal on <br />low slope areas. <br />Cap shingles are to be an exact color match and are to be manufactured by the same company as shingles. <br />NOTE: This home has a side bay window area on west side of building. Roof replacement is to include the <br />replacement of the metal roofed surface with a new matching metal roofing product manufactured to match <br />existing material, size, style and design. Replacement is to include needed new flashings, seam, and walls <br />sealants to prevent moisture infiltration. <br />Gutters: <br />2 Furnish and install new white or brown .027 ga. aluminum seamless gutters and downspouts <br />on home matching existing style and design. Gutters and downspouts shall be hung and secured in a manner <br />that effectively carries away storm water. Down spouts shall be installed so all gutters are serviced by at least <br />one. Install minimum 60" downs;wut extension with elbows at terminal ends of each downspout, all are to <br />extend at least to lawn areas. <br />3 Rebuild west side and rear brick chimneys by replacing all spalled or deteriorated brick then <br />re -pointing of all loose or deteriorated mortar joints. New brick shall match existing as close as possible. <br />Mortar joints shall be tooled and the color of mortar shall match existing as close as possible. If needed repair <br />or replace beveled concrete cap on both. Protect adjacent roof areas from tuck -pointing debris. <br />$ 1 TOTAL <br />Company Name: <br />Date: <br />CommuNiTy DEvLWrMEAT Ecoxohuc DEvELOPMEw FWA1.IciAL & PROGRAM <br />PAM -%C. MEYER DONALD E. INKS MANAGEMW <br />$741235-9660 $741235.9371 EUYA6E?N LEONARD <br />FAX- $741235-9697 5741235.9371 <br />
The URL can be used to link to this page
Your browser does not support the video tag.