Laserfiche WebLink
There are a few single -story cottages and one- and one - and -a- half -story bungalows. The most <br />prevalent fagade proportions are between a 1:1 and 1:2 height to width ratio. <br />Required <br />The height of a new structure and its height to width proportions shall be consistent with adjacent <br />buildings in the district. The building height shall be no greater than that of the tallest existing <br />structure and no less than that of the lowest existing structure in the same block. Fagade <br />proportion shall be established by permitting no structure with a fagade wider or narrower than <br />those existing in the same block. Additions to existing buildings shall be related in height and <br />proportion to the existing structure. <br />Recommended <br />Design of new construction should be compatible in character and mood to the building or <br />neighborhood. <br />Prohibited <br />Additions that would add new height or change the existing fagade of a building, and change its <br />scale and architectural character shall not be constructed. <br />Not Recommended <br />New stories should not be added nor existing stories be removed which would destroy important <br />architectural details, features and spaces of the building. Any style or period of architecture that is <br />incompatible with the existing should not be permitted in the new additions. <br />B. BUILDING MATERIALS <br />Wall materials in the district range from brick, stucco and wood clapboard and shingles, to <br />aluminum, vinyl and fiberboard/composite siding. <br />Required <br />Exterior materials used on a new structure shall be compatible in scale, texture and color (as <br />pertains to masonry) with adjacent structures. Materials used on an addition to an existing <br />structure shall relate to the existing or original materials of that structure. Also, as much of the <br />original structure as possible shall be retained so that the addition could be removed without <br />damage to the basic structure and appearance of the building. <br />Recommended <br />Alternative or composite siding may be used when it is the only feasible alternative. This siding <br />should be compatible with the original size and style and with the materials of other buildings <br />in the district. <br />Prohibited <br />Inappropriate materials such as asbestos, asphalt, cast stone or artificial brick shall not be used. <br />Not Recommended <br />Glass blocks should not be used. Concrete block should not be used for anything other than the <br />foundations. <br />STAFF RECOMMENDATION: Staff recommends approval. The new second storey addition <br />will be built on top of a non - contributing later addition to the original house. Although the <br />addition will be visible from the street there will be no original architectural features obscured by <br />the addition. The addition, as presented, will restore scale and balance to the rear of the house <br />and will be finished to match the exterior of the original house. <br />