Laserfiche WebLink
AAARVIN <br />Wi-ao.s 4.3 D00's . <br />CLAD ULTIMATE INSERT DOUBLE HUNG Madeforyou: <br />PRODUCT SPECIFICATION <br />SECTION. 08 5213 <br />ALUMINUM CLAD WOOD ULTIMATE INSERT DOUBLE HUNG WINDOW <br />PART GENERAL <br />1.1 SECTION INCLUDES ' <br />A. Aluminum clad wood ultimate insert (double hung) [single hung) and related [picture] [transom] window complete with hardware, <br />glazing, weatherstrip, [insect screen] [removable grille] (simulated divided lite) [grilles -between -the -glass] and standard or'specified <br />anchors, trim, and attachments. <br />1.2 RELATED SECTIONS <br />A. Section 0133 23 -Submittal Procedures: Shop Drawings, Product Data, and Samples. <br />B. Section 0162 00 -Product Options. <br />C. Section 0165 00 -Product Delivery. <br />D. Section 0166 00 -Product Storage and Handling Requirements. <br />E. Section 0171 00 -Examination and Preparation. <br />F. Section 0173 00 -Execution. <br />G. Section 0174 00 -Cleaning and Waste Management. <br />H. Section 0176 00 -Protecting Installed Construction. <br />I. Section 06 22 00 -Millwork: Wood trim other than furnished by window manufacturer. <br />J. Section 07 92 00 -Joint Sealants: SRI sealant and perimeter caulking. <br />K. Section 09 90 00 -Paints and Coatings: Paint or stain other than factory applied finish. <br />1.3 REFERENCES <br />A. American Society for Testing and Materials (ASTM): <br />1. E 283: Standard Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors. <br />2. E 330: Standard Test Method for Structural Performance of Exterior Windows, Curtains Walls, and Doors by Uniform Static Air <br />Pressure Difference. <br />3. E 547: Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure <br />Differential. <br />4. E 774: Specification for Sealed Insulated Glass Units. <br />5. C 1036: Standard Specification for Flat Glass. <br />B. American National Standards Institute I National Wood Window and Door Association (ANSI / NW WDA): I.S.4: Industry Standard for <br />Water Repellent Preservative Treatment for Millwork. <br />C. American Architectural Manufacturers Association / Window and Door Manufacturers Association (AAMA / WDMA): <br />101 / I.S.2-97: Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. <br />D. Window and Door Manufacturers Association (WDMA): 101 / I.S.2 WDMA Hallmark Certification Program. <br />,.,Iat <br />E. Sealed Insulating Glass Manufacturers Association / Insulating Glass Certification Council (SIGMA / IGCC). <br />F. American Architectural Manufacturers Association (AAMA): AAMA 2605 Voluntary Specification for High Performance Organic <br />Coatings on Architectural Extrusions and Panels. <br />G. National Fenestration Rating Council (NFRC): 101: Procedure for Determining Fenestration Product Thermal Properties. <br />1.4 SYSTEM DESCRIPTION <br />A. Design and Performance Requirements: <br />1. Window Units shall be designed to comply with AAMA / WDMA I.S.2-97 <br />a. Double Hung: H-LC30 up to 44 X 77.608 Inside Opening. <br />b. Transom: TR-LC30 up to 44 X 23.051 Inside Opening. <br />C. Picture: F-LC30up to 68 X 77.608 Inside Opening. <br />2. Air leakage shall not exceed the following when tested at LC -30 - 1.57 psf according to ASTM E 283: LC -30 - 0.30 cfm per <br />square foot of frame. <br />3. No water penetration shall occur when units are tested at the following pressure according to ASTM E 547: LC -30 - 4.5 psf. <br />4. Window assembly shall withstand the following positive or negative uniform static air pressure difference without damage when <br />tested according to ASTM E 330: LC -30 - 45 psf. <br />1.5 SUBMITTALS <br />A. Shop Drawings: Submit shop drawings under provisions of Section 0133 23. <br />B. Product Data: Submit catalog data under provisions of Section 01 33 23. <br />C. Samples: <br />1. Submit corner section under provisions of Section 0133 23. <br />2. Include glazing system, quality of construction, and specified finish. <br />D. Quality Control Submittals: Submit manufacturer's certifications indicating compliance with specified performance and design <br />requirements under provisions of Section of 33 23. <br />1.6 QUALITY ASSURANCE <br />A. Regulatory Requirements: Emergency Egress or Rescue: Comply with requirements for sleeping units of (IBC Basic Building Code) <br />1.7 DELIVERY <br />A. Comply with provisions of Section 0165 00. <br />B. Deliver in original packaging and protect from weather. <br />Z'06 19.2 <br />