Laserfiche WebLink
TEST 1: VOLUMETRIC LOADING CAPACITY <br />DATE: February 10, 2016 <br />SUBJECT: Plastic Refuse Container <br />PRODUCT IDENTIFICATION: Rehrig 95 EG ROC <br />TEST DESCRIPTION: To determine the volume of a container <br />MINIMUM PERFORMANCE STANDARD: The volumetric loading capacity of the container should be <br />measured according to ANSI Z245.30 (paragraph 7.2.4.2.1 and Appendix A). <br />TEST PROCEDURE: <br />1. The volume of the ROC is measured using the tank (immersion) method. <br />2. The empty ROC is placed inside a tank with sufficient capacity to receive the container to be <br />tested. The container must be level (that is, not inclined). <br />3. Simultaneously fill the tank and the container with water at a standard temperature (60 F). <br />4. Measure the volume of water inside the container to an accuracy of ±2 percent of the measured <br />capacity of the cart. <br />5. Repeat the capacity method. <br />6. The total volume is to be within tolerances on capacity according to product standard. <br />TEST RESULTS: <br />The ROC has a capacity of 95 gallons. Manufacturer can determine the difference between design and <br />real physical capacity based on these findings. <br />SUMMARY: The cart volume is 95 gallons capacity. <br />Appendix 1: Test setup photos. <br />SETE 6E4 September 28, 2016 Page 2 of 16 <br />