My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
RFQ - SBFD Solar PV - Ameresco
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2019
>
Opening of Quotations/Proposals
>
RFQ - SBFD Solar PV - Ameresco
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 2:19:26 PM
Creation date
8/28/2019 11:10:11 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
8/27/2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
P <br />Government Center Controls Upgrade <br />Existing pneumatic controls associated with seven (7) existing air handling units (AHU) throughout the <br />Government Center were removed and replaced with direct digital controls (DDC). <br />Additional installed equipment included: <br />• One (1) new hot water and one (1) new chilled water modulating flow control valve with electric <br />actuation for each of the AHUs <br />• New electric actuators, where required, for existing mixed air dampers and relief dampers <br />• One (1) new variable frequency drive (VFD) for each AHU supply fan motor <br />• Ninety-one (91) modulating flow control valves with electric actuation for all hot water reheat coils <br />associated with the variable air volume (VAV) boxes <br />• Ninety-one (91) wall mounted thermostats to control the VAV boxes <br />• New DDC programmable controllers for all existing convection heaters, cabinet heaters, unit <br />heaters, and exhaust fans <br />• New modulating flow control valves with electric actuation, where required, for existing <br />convection heaters, cabinet heaters, and unit heaters <br />• Thirty-one (31) DDC programmable controllers for the fan coil units (FCU) <br />• One (1) new hot water and one (1) new chilled water modulating flow control valve with electric <br />actuation in the return lines for each FCU <br />• Thirty-one (31) wall mounted thermostats to control the FCUs <br />How SaviM Were Determined — The Energy Savings for the Government Center Controls Upgrade were <br />calculated using eQUEST, which is a DOE2 energy simulation software. The baseline eQUEST input file details <br />the building components, occupancy schedules, lighting schedules, equipment efficiencies, etc. in order to <br />establish the building's baseline energy consumption. The modeled energy consumption was compared to, <br />and adjusted to match, the actual utility bill data. Modifications were then made to the baseline energy model <br />to simulate the energy savings that result from enabling new control sequences for the air handlers and fan <br />coils. <br />,; . .,„ <br />'G � 'r/./u/i %ice/%/, r�///i!!d/1 /�%/r(/,r1GJ�/.-/!rG/;///„.. / <br />City of South Bend —August 27, 2019 38 11. Measurement & Verification <br />' eqe content is subject to Confidentiality Restrictions" <br />
The URL can be used to link to this page
Your browser does not support the video tag.