My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - 315 & 319 W Jefferson Exterior Renovations Project No 119-064 - Slatile Roofing & Sheet Metal
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2019
>
Opening of Bids
>
Opening of Bids - 315 & 319 W Jefferson Exterior Renovations Project No 119-064 - Slatile Roofing & Sheet Metal
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 8:40:36 AM
Creation date
8/15/2019 8:48:26 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
8/13/2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Sure -Weld T <br />Reinforced Membrane <br />1. Sure -Weld TPO roofing systems are quick to install, as minimal labor 3. <br />and few components are required. TPO systems are installed using an <br />Automatic Heat Welder, making sheet welding fast, clean, consistent, <br />and easy to learn, while reducing strain on the roofing technician. <br />2. APEEL Protective Film should be removed from within areas that <br />are to be heat -welded together. In areas that do not require heat - <br />welding, the APEEL Protective Film can be left in place for up to <br />90 days. When the installation of the entire TPO roofing system is <br />complete, remove and discard the APEEL Protective Film. <br />Physical Property <br />Tolerance on Nominal Thickness, %ASTM D751 test method <br />Thickness Over Scrim, in. (mm) <br />ASTM D7635 optical method, average of 3 areas <br />Breaking Strength, Ibf (kN) <br />ASTM D751 grab <br />Elongation Break of Reinforcement, % <br />ASTM D751 grab method <br />Tearing Strength, Ibf (N) <br />ASTM D751 proc. B 8 in. x 8 in. <br />Brittleness Point, °F (°C) <br />ASTM D2137 <br />Linear Dimensional Change, <br />ASTM Of 204, 6 hours at 158°F <br />Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm,168 hrs <br />Water Absorption Resistance, mass <br />ASTM D471 top surface only 166 hours at 158°F water <br />Factory Seam Strength, Ibf (N) ASTM D751 grab method <br />Field Seam Strength, Ibf/in (kN/m) <br />ASTM D1876 tested in peel <br />Water Vapor Permeance, Perms <br />ASTM E96 proc. B <br />Puncture Resistance, lbf (kfd) <br />FT 101C, method 2031 (see supplemental section) <br />Properties After Heat Aging <br />ASTM D573, 32 weeks @ 240°F or 8 weeks Q 275°F <br />No cracking when bent around 3" diameter mandrel <br />Weight Change, <br />Typical Weights Ib/ftz (kg/mz) <br />The Carlisle Mechanically Fastened Roof System installation <br />starts by fastening the insulation with a minimum of 4 fasteners per <br />4' by 8' board. The membrane is mechanically fastened to the deck <br />using HP-X"' Fasteners and Piranha Plates'"' or HP-XTRA Fasteners <br />and Piranha XTRA Plates. Adjoining sheets of membrane are <br />overlapped over the fasteners and plates and joined together with a <br />minimum 1�/2"-wide (4 cm) hot-air weld. <br />ASTM D6878 Requirement <br />45-mil <br />+15, -10 <br />± 10 <br />0,015 min <br />0.018 typical <br />(0.380) <br />(0,457) <br />220 (976 N) <br />225 (1.0) min <br />min <br />320 (1.4) typical <br />15 min <br />15 min <br />25 typical <br />55 (245) min <br />55 (245) min <br />130 (578) typical <br />-40 (40) max <br />-40 (40) max <br />-50 (46) typical <br />1 max <br />PASS <br />3.0 max <br />66 (290) min <br />No requirement <br />No requirement <br />No requirement <br />PASS <br />No cracking <br />1.5 max <br />1 max <br />-0 2 typical <br />PASS <br />3.0 max <br />0.90 typical <br />66 (290) min <br />25 (4.4) min <br />50 (8.8) typical <br />0.10 max <br />0.05 typical <br />250 (1.1) min <br />325 (1.4) typical <br />PASS <br />No cracking <br />1.0 max <br />0.23 (11) <br />60-mil <br />±10 <br />0.024 typical <br />(0.610) <br />250 (1.1) min <br />360 (1.6) typical <br />15 min <br />25 typical <br />55 (245) min <br />130 (578) typical <br />-40 (-40) max <br />-50 (-46) typical <br />+ 1 max <br />-0.2 typical <br />PASS <br />3.0 max <br />R90 typical <br />66 (290) min <br />25 (4.4) min <br />60 (10.5) typical <br />0.10 max <br />0.05 typical <br />300 (1.3) min <br />350 (1.6) typical <br />PASS <br />No cracking <br />1.0 max <br />0.29 (1.4) <br />80-mil EXTRA <br />±10 <br />0.034 typical <br />(0.864) <br />350 (1.6) min <br />425 (1,9) typical <br />15 min <br />25 typical <br />55 (245) min <br />130 (578) typical <br />-40 (-40) max <br />-50 (-46) typical <br />+ 1 max <br />-0.2 typical <br />PASS <br />± 3.0 max <br />0.90 typical <br />66 (290) min <br />40 (7.0) min <br />70 (12.3) typical <br />0.10 max <br />0.05 typical <br />400 (1.8) min <br />450 (2.0) typical <br />PASS <br />No cracking <br />1.0 max <br />0.40(20) <br />Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the <br />specification range for any particular property of this product. <br />
The URL can be used to link to this page
Your browser does not support the video tag.