Laserfiche WebLink
NW��r� pa Ufliif es and Service Lines Rules and Ctions <br />_._. __._.________.t <br />require its demolition at the customer's expense after giving a ninety <br />(90) day notice. Water service may be discontinued prior to ninety (90) <br />days as described herein, Section VIII. - DISCONNECTION OF <br />SERVICE. It is the customer's responsibility to notify the Utility prior <br />to any modifications of the customer's utility facilities. <br />When service connections are made as a part of the initial installation <br />of "on site" mains by a developer's plumber, or when service <br />connections are made to existing mains by the developer's plumber, the <br />Utility will allow such connections provided the developer and their <br />plumber abide by the Utility's requirements as herein described and <br />specifications determined by the Utility's engineering department. <br />The developer shall guarantee in writing their work for a period of not <br />less than three (3) years. <br />Specifications for sewer service lines shall conform to the Municipal <br />Building Code and City Engineering Department Standards. <br />Customers desiring to install or to make modifications to their sewer <br />service facilities should contact the City engineering department. <br />B. Installation Requirements <br />1. Size and Material <br />The minimum inside diameter of all newly laid service lines <br />shall be one inch. Nonmetallic, lead or galvanized steel pipe are <br />prohibited whether on public or private property. Service lines <br />shall be ductile cast iron or Type K copper from the main to the <br />front of the building. The water line shall have one (1) foot extra <br />length, or waviness, to allow for ground movement. <br />2. Location <br />The Utility reserves the right to determine the location or to <br />order relocation of water service lines and appurtenances if <br />noncompliant with these Rules. Each premise to be served shall <br />have a separate water service line. However, two lines for <br />adjacent properties may be run in the same trench provided they <br />are at least four (4) feet apart. Water service lines shall, where <br />possible, run straight and perpendicular to the long axis of the <br />main. Lines shall be at least ten (10) feet horizontally from any <br />sanitary sewer line, and at least one (1) foot above the sewer line <br />if they cross. The water line shall have a minimum earth cover <br />of five (5) feet and a maximum of six (6) feet. Backfill and <br />tamping shall conform to AWWA specifications and the <br />Municipal Code. Service lines may not be placed under <br />driveways or parking lots where possible. Leaks on such lines <br />will not be covered by the water service fund. Residential <br />service lines shall be located approximately four (4) feet laterally <br />from the side property line on either side of the parcel unless <br />M <br />