My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Change Order No 1 - Gemini at Washington Colfax Apts Masonry and Stair Repair Div A Proj No 118-080B - Bokon Masonry Inc
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2019
>
Change Orders
>
Change Order No 1 - Gemini at Washington Colfax Apts Masonry and Stair Repair Div A Proj No 118-080B - Bokon Masonry Inc
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 11:16:52 AM
Creation date
5/29/2019 10:48:44 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
5/28/2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
INTER -OFFICE MEMORANDUM <br />DEPARTMENT OF PUBLIC WORKS <br />DIVISION OF ENGINEERING <br />TO: Linda M. Martin, Clerk <br />Board of Public Works <br />FROM: Kyle Silveus <br />SUBJECT: Change Order No. 1 <br />DATE: May 24, 2019 <br />reeror�am9 inmer��un..�rou. rr�uumeuuuu�momr ua�pi�r�m�w�uv�,�rcmrr�m umimawrc�u�nuumm�mr nu:ui. aus�rtar�fi�,r�a�i rrm✓r run+�u:�ui naerv�s�r eee��o uwnoGn.. iummmxnooxrnrmn.nrx mrvoinam�rmm.�v�mmawra�mx�wrwt��rp�ua�er�at sRr vrwv¢�awu��wvr� �nadWuio �tir�.mwsra�uim�nm�,� <br />The apartments known as Gemini at Washington and Colfax are being renovated. <br />Improvements include roof repair, fire stair replacement, and masonry repair. <br />The project has encountered an unforeseen condition that were not reasonably foreseen during <br />the design phase and is going beyond 20% of the contract value. It was not possible to know <br />the condition of the masonry behind the existing fire stairs prior to their removal. The single <br />Wythe of brick must support the new fire stairs and therefore must be repaired before the <br />contractor can complete the stairway installation. Brick at the southernmost fire stair is in <br />particularly poor condition. Limited repair is not appropriate for this stair. The other three stair <br />shafts are in better condition such that repairs can be limited to just what is required to secure <br />the new stairs. Safety is an issue as the stairways must be securely anchored to the building. <br />Please call with your questions, <br />
The URL can be used to link to this page
Your browser does not support the video tag.