My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotes - North & South Cleveland Well Fields Refurbishments-Program Related Items Project No 118-021A - Service One Industrial
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2019
>
Opening of Quotations/Proposals
>
Opening of Quotes - North & South Cleveland Well Fields Refurbishments-Program Related Items Project No 118-021A - Service One Industrial
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 2:12:03 PM
Creation date
3/27/2019 1:47:05 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
3/26/2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
y <br />PtioNE 574/ 235-9251 <br />FAX 574/ 235-9171 <br />TDD 574/ 235-5567 <br />CITY OF SOUTH BEND PETE BUTTIGIEG, MAYOR <br />BOARDOF PUBLIC WORKS <br />Cleveland Well Fields Refurbishments — <br />Program Related Items (Project Number) <br />118-021A <br />Addendum No. 1 <br />Date: March 21, 2019 <br />To: All Planholders <br />From: Becca Plantz, Project Engineer <br />The following information were questions at site visits with answers that could change, clarify, <br />or affect the contract documents, including quote tab: <br />Q: Does all hardwire need to be replaced? <br />A: Yes, all hardwire shall be replaced. <br />Comment: A new junction box or junction box holding router directly of current PLC could be <br />used to fit PLC inputs and conduit down to the old box due to the lack of space in the original <br />box. <br />Q: Is existing program available? <br />A: Yes, existing programming can be provided. Programming is planned to be switched but is <br />still being finalized. This can be provided when completed. <br />Q: In regards to the base bid — which does not include a touchscreen, does this mean the existing <br />HMI will no longer be used, or does it need the program modified to work with the new <br />processor. <br />A: HMI to stay on the junction box for the PLC and be programmed with new processor unless <br />touch screen is quoted. <br />Q: If it is to be reprogrammed, is the hardware compatible with the new processor? <br />A: The hardware is technically compatible with the current PLCs, however looking at the <br />program for Cleveland South, there isn't any free Input/Output space for the 4-20mA and digital <br />alarm signals to go into and there is no more room on that rack to add any additional input cards, <br />so that one will require replacement. Cleveland North has additional rack space to accommodate <br />I/O, but an upgraded panel there would be preferred. <br />
The URL can be used to link to this page
Your browser does not support the video tag.