Michigan Department of Licensing Inspection Number: 1093271 <br />and Regulatory Affairs Inspection Date(s): 09/21/2015 - 09/21/2015 <br />530 West Allegan Street Issuance Date: 10/01/2015 <br />P.O, Box 30645 Optional Reporting Number: 15-158/21 <br />Lansing, MI 48909 <br />Phone: (517) 284-7680 Fax: (517) 284-7685 <br />Citation and Notification of Penal <br />Company Name: Hardman Construction, Inc. <br />Inspection Site: CR 420 Bridge over Escanaba River, Gladstone, MI 49837 <br />Citation 1 Item I <br />Type of Violation: Other -than -Serious <br />408.40722(1): CS Part 7, Welding and Cutting <br />An oxygen cylinder shall be stored not less than 20 feet from fuel gas cylinders or any highly combustible <br />material, such as, but not limited to, oil, grease, excelsior, flammable gas, or a source of ignition, or shall be <br />separated from the material by a noncombustible wall not less than 5 feet (1.6 meters) high which has a fire <br />resistance rating of 30 minutes. <br />Employees installing form boards on CR 420 Bridge were walking by two oxygen tanks setting 5' from two <br />acetylene tanks and 9' from a diesel storage tank. <br />Date By Which Violation Must be Abated:,' October 04, 2015; <br />Proposed` Penalty; $0.00 <br />Authorized Slgnatore <br />See paagpa I through 3 of this Citation and Notification of Paninhy for information on employer and cniployce righis and responsihil'ides. <br />Citation ind Nofifikatioo o0enalh — �_ <br />I age 4 of 5 MIOSU-2 (Rev. Gh)M) <br />