Laserfiche WebLink
Public Works and Other Facilities <br /> ADA Barrier Priorites <br /> Facility <br /> I.Accessible 2.Access to Goods and 3. Usability of Rest Rooms 4.Additional Access <br /> Approach/Entrance Services <br /> © There are no curb cuts at No ADA Barrier Present No ADA Barrier Present No ADA Barrier Present <br /> Building Department locations of drop offs or <br /> 125 S.Lafayette Blvd. handicap parking areas.There <br /> are no van accessible <br /> handicap spots. <br /> Second accessible entrance Alarms should be the variety Improper bathroom signage. No ADA Barrier Present <br /> requires signage.Sign needed equipped with flashing lights. <br /> Central Service Building to denote van accessibility Signage installed at wrong <br /> 1045 W.Sample St. parking space.Carpeting/mats heights,&lack Braille. <br /> not secured at edges. <br /> No ADA Barrier Present Need to lower heighth of call Need to provide signs on each No ADA Barrier Present <br /> buttons for elevators on all public floor indicating where <br /> public floors,current height is accessible bathrooms are <br /> above 42 inches.Also there Both bathrooms on ground <br /> are not signs on both sides of level and 4th floor need to <br /> the elevator door jamb have signs mounted on latch <br /> indicating floor level.On floors side of the door.Signs on 4th <br /> 4,12,13,14,and in the court floor are lacking braille on <br /> room/13th conference room, them.Handles on 4th floor are <br /> there needs to be designated inaccesible.4th floor bathroom • <br /> County City Building handicap seating available. does not have a 36 inch wide <br /> 227 W.Jefferson Blvd. Court room handles are path to all fixtures.Stalls on <br /> inaccessible.On fllors 4,12, both floors may need new <br /> 13,and 14 the counters are all handles that are more easily <br /> too high except for city clerk accessible.4th floor bathroom <br /> office.Also in the conference needs grab bar behind toilet. <br /> room the aisles are too narrow Toilet seats on both floors sit <br /> between seats.Court room too low(14 and 16 inches <br /> doors are too heavy. high).In basement bathroom <br /> there is not 29 inches from the <br /> floor to the bottom of the <br /> lavatory. <br /> Humans Right No ADA Barrier Present No ADA Barrier Present No ADA Barrier Present No ADA Barrier Present <br /> Commission <br /> 319 N.Niles Ave. <br /> Stripe parking lot for ADA Replace door knobs with pull Add signs denoting the Not applicable <br /> accessible spaces and van handles and panic hardware. accessible entrance, <br /> © Waste Water: accessible spaces.Locate Adjust interior and exterior accessible restrooms,etc. <br /> Administrartion ADA accessible parking space doors for opening pull force. <br /> 3113 Riverside Dr. nearest the accessible route. Adjust interior and exterior <br /> doors closers for 3 seconds or <br /> more closing time. <br /> Parking lot handicapped Fire alarms must be type that Faucets in restrooms Water fountains compliant. <br /> spaces need code-compliant flash when active. inoperable for people with <br /> signage posted. mobility impairments,install <br /> "paddle type"handles.Soap <br /> dispensers/paper towels and <br /> le Water Works:Colfax cabinets must be no higher <br /> Office <br /> 125 W.Colfax Ave. than 48"from the floor. <br /> Additionally,the mirror's <br /> bottom edge should be no <br /> more than 40"from the floor <br /> (alternatively,it may be angled <br /> downward instead). <br /> Stripe parking lot for ADA Replace door knobs with pull Upgrade rest room facility for Water fountain is too high <br /> accessible space.Locate ADA handles and panic hardware. ADA accessibility(stall, <br /> accessible parking space Adjust interior and exterior lavatory bottom height, <br /> nearest the accessible route. doors for opening pull force. hardware,toilet seat height, <br /> Add signs denoting the Adjust interior and exterior door tactile signs) <br /> accessible entrance. closers for 3 second or more <br /> ©Waste Water:Dewatering closing time.Add railing and/or <br /> 3113 Riverside Dr. floor markings for accessible <br /> routes due to low clearances <br /> near machinery.Update <br /> emergency egress signs for <br /> flashing lights and audible <br /> signals.Provide signage for <br /> rooms. <br /> Attachment 3-2 <br />