Laserfiche WebLink
QUESTIONS POSSIBLE SOLUTIONS <br /> Yes No <br /> Doorways and Passages, continued <br /> Are pictograms or symbols used to identify ❑ ❑ 0 If symbols are used,add <br /> rest rooms, and, if used, are raised characters supplementary verbal signage <br /> and braille included below them? with raised characters and <br /> braille below pictogram symbol. <br /> Q Is the doorway at least 32 inches clear? ❑ ❑ 0 Install offset(swing-clear)hinges. <br /> O Widen the doorway. <br /> tear width <br /> QAre doors equipped with accessible handles ❑ ❑ ❑ Lower handles. <br /> (operable with a closed fist),48 inches high 0 Replace knobs or latches with <br /> or less? lever or loop handles. <br /> height 0 Add lever extensions. <br /> O Install power-assisted or <br /> automatic door openers. <br /> QCan doors be opened easily (5 lbf maximum ❑ ❑ 0 Adjust or replace closers. <br /> force)? 1 0 Install lighter doors. <br /> O Install power-assisted or <br /> automatic door openers. <br /> QDoes the entry configuration provide adequate ❑ ❑ ❑ Rearrange furnishings such as <br /> maneuvering space for a person using a ri chairs and trash cans. <br /> wheelchair? l ❑ Remove inner door if there is a <br /> clear widti, vestibule with two doors. <br /> A person in a wheelchair needs 36 inches 0 Move or remove obstructing <br /> of clear width for forward movement,and a partitions. <br /> 5-foot diameter or T-shaped clear space to <br /> make turns.A minimum distance of 48 <br /> inches clear of the door swing is needed be- <br /> tween the two doors of an entry vestibule. <br /> QIs there a 36-inch-wide path to all fixtures? ❑ ❑ 0 Remove obstructions. <br /> width <br /> Stalls (ADAAG 4.17) <br /> Is the stall door operable with a closed fist, ❑ ❑ 0 Replace inaccessible knobs <br /> inside and out? with lever or loop handles. <br /> ❑ Add lever extensions. <br /> QIs there a wheelchair-accessible stall that has ❑ ❑ 0 Move or remove partitions. <br /> an area of at least 5 feet by 5 feet,clear of the 0 Reverse the door swing if it is <br /> door swing, OR is there a stall that is less ac- safe to do so. <br /> cessible but that provides greater access than a length/ <br /> width <br /> typical stall (either 36 by 69 inches or 48 by 69 <br /> inches)? <br /> Checklist for Existing Facilities version 2.1 ©revised August 1995,Adaptive Environments Center,Inc.for the National Institute on <br /> Disability and Rehabilitation Research.For technical assistance,call 1-800-949-4ADA(voice/TDD). <br /> Attachment 2-10 <br />