My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6C (7)
sbend
>
Public
>
Redevelopment Commission
>
Agendas & Packets
>
2012
>
04-24-12 Packet
>
6C (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2012 10:27:14 AM
Creation date
4/20/2012 12:33:16 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
�1 r ' -S <br />A S S 0 C I A T E S I N C <br />September 21, 2011 <br />Mr. Chad M. Smitley, PE <br />BSA Life Structures <br />9365 Counselors Row <br />Indianapolis, Indiana 46240 <br />RE: Proposal for Preliminary Geotechnical Engineering Investigation <br />Proposed Development at Ignition Park <br />South Bend, Indiana <br />ATC Proposal No. 023G- 2011 -0176 <br />Dear Mr. Smitley: <br />www. atcassociates. corn <br />2224 Industrial Drive, Suite A <br />Highland, IN 46322 <br />Phone: 219- 922 -7235 <br />Fax: 219- 922 -7243 <br />As per your request, ATC Associates Inc. (ATC) is pleased to submit the following proposal for <br />conducting a geotechnical investigation for the subject project. <br />ATC is a nationwide engineering consulting firm that specializes in geotechnical engineering, <br />environmental engineering, construction materials testing and inspection services. For detailed <br />company information, please visit our web site at www.atcassociates.com. <br />PROJECT INFORMATION <br />We understand that the Ignition Park, which covers approximately 80 acres of vacant land, will be <br />developed in South Bend, Indiana. No detailed layout of the proposed development is available at this <br />time. We have been informed that the proposed development will likely have one to two story office <br />buildings with no basements. For the purpose of the proposal, we assume that the proposed buildings <br />will be supported on shallow foundations, In the absence of any loading information, we assume that <br />the wall and column loads will reportedly not exceed about 5 kips per lineal ft and 200 kips per column, <br />respectively. The finished ground floors will presumably be at or near the existing ground surface. The <br />site is currently a vacant lot that was reportedly developed in the past. No information regarding the <br />past development was provided. <br />The purpose of this investigation is to obtain preliminary information regarding the subsurface soil and <br />groundwater conditions noted at 12 selected boring locations. Once the layout of the development is <br />finalized, additional soil borings and analysis will be required to develop final geotechnical <br />recommendations. <br />SCOPE OF WORK <br />1. ATC will prepare a health and safety plan (HSP) prior to any field activities. The drawings provided <br />to us will be utilized to determine the boring locations at the site. We request that an existing <br />ground surface topographic map be provided to estimate the ground surface elevations for each <br />boring location. No surveying is included in the proposal. <br />
The URL can be used to link to this page
Your browser does not support the video tag.