Laserfiche WebLink
LIM <br />1. Objective <br />AMD003 (2) <br />2 of 10 <br />Issue Date: 0,809,04 <br />Revision Date: 160930 <br />To verify that the oxygen tank retention system(s) meets the minimum load requirements. This <br />applies to standard oxygen tanks and any holders for portable oxygen tanks. <br />2. Test Equipment - Check all equipment for calibration compliance <br />21 Kestrel Pocket weather tracker. Model 4000 (TL01 6) <br />2.2 Hand Pump Hydraulic Cylinder (TL045) <br />2.3 5000lb Load Cell & Digital Display (TL021, TL025) <br />2.4 <br />2.5 <br />3. Test Specimen <br />REV Oxygen H-Tank Retention System, The retention, system consisted of one (1) retention <br />frame, three (3) body straps, and one (1) yoke strap. The retention system was mounted to a <br />rigid base with eight (8) 1/4-20 UNC Hex Head F593 Stainless Steel bolts, 1/4-20 Stainless <br />Steel Nuts, and: 1/4 x 1 OD Stainless Steel Fender Washers. <br />4. Test Set -Up <br />Reference following page(s) for instructions. <br />5. Procedure & Test Results <br />Reference following page(s) for instructions. <br />6. Conclusions <br />7. Pictures <br />REV Oxygen H-Tank Retention, System met or exceeded the requirements of <br />SAE J3043 - Ambulance Equipment Mount Device or Systems and <br />AMD 0013 - Oxygen Tank Retention System Static Test <br />Take Pictures to document test procedure. <br />ACC Climate Control a Valeo brand • 22150 Challenger Drive • P.O. Box 1905 ► Elkhart, IN 46515-1905 <br />P(574) 264-2190 • F(574) 266-6744 - soles,@acecliniatecontrol.com • wwww.acccliniatecontrol.co►n <br />2017-010 REV Orlando SAE J3043, AMD003 02 Wrank Retention <br />S:\ <br />