My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - Spec S - One or More 2018 or Newer Emergency Medical Vehicle - Fire Service Inc - Part 1
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2018
>
Opening of Bids
>
Opening of Bids - Spec S - One or More 2018 or Newer Emergency Medical Vehicle - Fire Service Inc - Part 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2025 11:51:13 AM
Creation date
8/30/2018 9:12:56 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
8/28/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
10083-0016 <br />CITY OF SOUTH BEND <br />capacity. <br />A complete litter fastener assembly shall be furnished, The installed litter fastener <br />device for wheeled cots shall meet the performance requirements of SAE J3027. <br />The litter fastener device shall be installed according to the litter fastener <br />manufacturer's instructions, The ambulance floor and substructure shall be <br />tested in accordance with the dynamic requirements of SAE J3102. <br />The ambulance shall have a piped medical oxygen system capable of storing <br />and supplying the minimum requirements in liters of medical oxygen as specified <br />by the purchaser. The installed medical oxygen piping shall be leak tested to 80 <br />PSI. After the successful completion of piping test, the system shall be <br />completely assembled and the flow rate of the outlets tested with the system <br />pressurized at normal working pressure, The system shall be capped then <br />tagged with date and signature of person and firm performing the tests. <br />Dolphin, Sound Deadeninci, Full interior, 160" or larcier Module <br />0810 R1 01 UO3W303 XONHOW1 <br />The entire interior of the module body shall be sprayed the Dolphin HydroArmor <br />rubberized undercoating. A sprayable, corrosion preventing, non-flammable, latex <br />coatings designed to red -ace sound transmission through a variety of substrates <br />including cold rolled steel, galvanized steel, stainless steel, primed steel, <br />aluminum, fiberglass and plywood. <br />Tests of HydroAnnor 7775 and 7778 show these coatings are extremely durable <br />under even the worst service conditions. HydroArmor 7775 and 7778 coated <br />panels have been tested to several days at 250' F and to immersion in acidic and <br />caustic solutions; these tests did not affect the dried film. Exposure to anti -freeze, <br />motor oil, transmission fluid, and washer fluid did not affect the corrosion <br />protection of the coating. Rocks bounced off the coating when test panels were <br />subjected to the "Gravelometer" at -40' C. After weeks of exterior exposure <br />cycling, the HydroArmor coating remains intact and there is no adhesion loss. <br />Type 9 - 170" Module - Custom Series <br />VEHICLE BODY AND PATIENT AREA <br />BODY ACCOMMODATIONS <br />The ambulance body and patient compartment shall be sufficient in size to meet <br />the requirements of paragraph 3. 10. 1 of Federal Specification KKK -A- I 822-F. <br />The interior layout shall be such that a technician can administer life support <br />treatments to at least one person during transport. The modular body shall be <br />(170") one hundred seventy inches in length and (95 ") ninety five inches in width. <br />PATIENT COMPARTMENT INTERIOR DIMENSIONS <br />08/27/18 <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.