Laserfiche WebLink
Page4:53 <br />Header: 17.1 Equipment Furnished <br />Exception: PL Custom offers as a standard an HVAC unit that is more superior to <br />the specified unit. 38,000 BTU cooling vs. the specified 32,000 BTU and 60,000 <br />BTU heating vs. the specified 35,000 BTU. See out proposal Ducted Heater and <br />Air Conditioning page 46. <br />Page #: 53 <br />Header: 18.0 ALS Cabinet <br />Exception. Layout and dimensions vary slightly and the upper cabinet has (2) <br />vertically hinged doors vs. the specified (1) top hinged door. Allowing greater <br />access and more user friendly space. Proposed is (2) shelves for the lower <br />portion of the ALS due to configuration of the entire ALS cabinet. <br />Page #: 53 <br />Header: 19.0 Vacuum Formed Upholstery <br />Exception: PL Custom offers as a standard a heavier more durable vinyl with a <br />very dense foam that will not break down over years of use. <br />Page #: 55 <br />Header: 22.7 Oxygen Bottle Storage, 22.8.1 Additional Oxygen Bottle Storage <br />Exception: PL Custom offers as a standard a recessed (2) bottle storage area next <br />to the side entry door stepwell along with strapless, crash tested and approved <br />Zico bottle holders. (2) Zico Strapless Oxygen Bottle Holders will be provided in <br />the exterior oxygen compartment for a total of (4) portable oxygen bottles being <br />carried and secured in the ambulance. <br />Page #: 55 <br />Header: 22.9 Squad Bench Cabinet <br />Exception: Lexan with be provided vs. the specified Plexiglas <br />