211 5outh Prairie 5treet, PO Box 127 <br />Rolling Pr�airie, IN 463,71-0127 <br />219 778-2591 Fax: 219 778-2592 <br />Spec G Front -Load Refuse Truck <br />Specifications Deviations <br />-Page 11 Fuel tanks. Three 25 "x 80" tanks for 102.5 DGE capacity. <br />-,Page I I Cab. Mack LR 64 R G cab with left and right-hand drive. <br />-Page 12 Section C #1. Floor has radius design to act as a I 00-gallon sump <br />for liquids in the load. This prevents liquids slopping over the bulkhead. <br />#3a. Lower hopper sides are 3/16" 100 K steel. <br />#4b. Body floor is 1/4" 1 OOK steel. <br />-Page 13 Section C #6b. Horizontal bracing meets the purpose and the <br />specification stated is proprietary. <br />-Page 15 Section D #9b. EZ Pack utilizes only 2 cylinders on the tailgate <br />that lifts, lowers, and locks the tailgate, Only two are required. <br />-Page 16 Section E #7. EZ Pack does not utilize a clamp -on design to secure <br />the arms. <br />#9. Metered cylinders are not used. <br />#10a. Forks are I" thick T-1 steel. <br />#11. No transducers are used. <br />-Page 17 Section F #2. Unit has a Muncie MLS pump with a flow -regulated <br />system. Has a no -kick -out feature when dumping containers. This allows the <br />driver to pack on the run without overheating. <br />,-Page 18 Section L EZ Pack meets the purpose. The specification listed is <br />proprietary. <br />g. Valve is not located under the body. <br />-Page 19 Section 1 #1. No PLC needed. <br />#2 EZ Pack utilizes relays. <br />�-Page 19 Section J #2. A separate joystick is provided to operate the carry <br />can. <br />-Pag�c 20 Section J #3b. Red button not required. There is a separate <br />joystick to operate the carry can. <br />