Laserfiche WebLink
(D)New construction and substantial improvements shall be constructed by <br />methods and practices that minimize flood damage; <br />(E) Electrical, heating, ventilation, plumbing, air conditioning equipment, utility <br />meters, and other service facilities shall be located at/above the FPG or designed <br />so as to prevent water from entering or accumulating within the components <br />below the FPG. Water and sewer pipes, electrical and telephone lines, <br />submersible pumps, and other waterproofed service facilities may be located the <br />FPG; <br />(F) New and replacement water supply systems shall be designed to minimize or <br />eliminate infiltration of flood waters into the system; <br />(G) New and replacement sanitary sewage systems shall be designed to minimize or <br />eliminate infiltration of flood waters into the system; <br />(H) On-site waste disposal systems shall be located and constructed to avoid <br />impairment to them or contamination from them during flooding; <br />(I) Any alteration, repair, reconstruction or improvements to a structure that is in <br />compliance with the provisions of this ordinance shall meet the requirements of <br />"new construction" as contained in this ordinance; and, <br />(J) Any alteration, repair, reconstruction or improvement to a structure that is not in <br />compliance with the provisions of this ordinance, shall be undertaken only if <br />said non-conformity is not further, extended, or replaced. <br />(K) Whenever any portion of the SFHA is authorized for use, the volume of space <br />which will be occupied by the authorized fill or structure below the BFE shall <br />be compensated for and balanced by an equivalent volume of excavation taken <br />below the BFE. The excavation volume shall be at least equal to the volume of <br />storage lost (replacement ratio of 1 to 1) due to the fill or structure. <br />i.. The excavation shall take place in the floodplain and in the same property in <br />which the authorized fill or structure is located; <br />ii. Under certain circumstances, the excavation may be allowed to take place <br />outside of but adjacent to the floodplain provided that the excavated volume <br />will be below the regulatory flood elevation, will be in the same property in <br />which the authorized fill or structure is located, will be accessible to the <br />regulatory flood water, will not be subject to ponding when not inundated by <br />flood water, and that it shall not be refilled; <br />iii. The excavation shall provide for true storage of floodwater but shall not be <br />subject to ponding when not inundated by flood water; <br />iv. The fill or structure shall not obstruct a drainage way leading to the <br />floodplain; <br />Page 20 of 31 <br />