Laserfiche WebLink
• 1200 Courm•-Crtr B~nLninc <br />?Z7 W. JEFFEk50N BOULEI'ARll <br />3ovrra BeNn, 1N~lANA 46601-1830 <br />PrtoNE 5741235-9371 <br />~5~~ ~'~1 <br />~~s~ ~~ ~1'~~;j~ <br />CITY OF SOtrrr=. BEND STEPN I:N ]. LUECKE, .MAYOR j~~~ <br />COMMUNITY SL ECONOMIC DEVELOPM NT <br />~~1, <br />]EFFREY V. GTBNEY `~""""°""".».",~ ~' <br />EXECUTIVE DIRECTOR <br />Property Address: 1806 E. Fox St <br />Property Ovvners: Lisa Anderson-Callahan 289-7780(h) 339-0282(eell) <br />Date: Februar~7, 20]0 <br />Inspector: Jeff Yount? <br />Program: Home Repair& Im.~rovement Program <br />Roof (House),.;, <br />I i/ ~ s 6' • Tear-off all roof coverings down to bare wood deck on al] surfaces. Replace or repair all <br />deteriorated framing members and sheeting. On all areas install 7/16" OSB sheathing over decking to provide <br />level and adequate nailing surface for new roofing, then with new "TITANIUM-UDL" Synthetic Roof <br />Underlayment or approved equal, premium (1'/z") metal drip edge along all roof edges, appropriate pipe boots <br />and Owens Corning or Cora-Vent brand comigated vinyl roof ridge vent for proper attic ventilation, needed <br />transition flashing, step and counter flashing at vertical transitions. Install "Ice & Water" shield along roof <br />eaves and in valleys. Install 23~-240 lb. Oakridge dirnensionaI, or GAF Timberline dimensional or approved <br />equal on all pitched roof surfaces a one ply rubberized roof system or an approved equal on low slope areas. <br />Note: Reattach and/or replace any missing aluminum fascia and soffiting. <br />Cap shingles are to be an exact color match and are to be manufactured by the same company as shingles. <br />Gutters: (Hous~ <br />2 ~7s. = Furnish and install new white or brown (per homeowner) .02"/ ga. aluminum seamless <br />gutters and downspouts on home. Gutters and downspouts shall be hung and secured in a manner that <br />effectively carries away storm water. Down spouts shall be installed so all gutters are serviced by at least one. <br />Install minimum 60" downspout extension with elbows a[ terminal ends of each downspout, all are to extend <br />at least to lawn areas. Cover all with nesv metal lcaf~uard (expanded aluminum 4' sections with rigid <br />mounting flames) <br />Miscellaneou arepairs; <br />4 3 7S . `-`' Replace broken pane of insulated glazing in rear bedroom vinyl window unit. The existing <br />opening is to be secured with a solid covering while sash is in process ofbeing re-glazed. Repair, to the extent <br />possible, any damage to interior and exterior window unit from previous and current boarding up of unit. <br />r~ (~co, '1'O'1'AL <br />CAMMiSNI'rY Deve>_orMeNT ECONOMIC DEVELOPMENT I;INANCIAL EL C'ROGRAM <br />PAMELI C- MEl'EA t70NALD E- INKS MANAGF1vlFNT <br />5741235-9GG0 574+135-9371 I.uv~eErri LEOxnun <br />F.+x 574!235-7G97 5741235-9371 <br />