My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - Hibberd Plaza and Streetscape Proj No 117-063R - R. Yoder Construction, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2018
>
Opening of Bids
>
Opening of Bids - Hibberd Plaza and Streetscape Proj No 117-063R - R. Yoder Construction, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2025 3:06:36 PM
Creation date
3/14/2018 9:25:44 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/27/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ADDENDUM NO.3 <br />To the Contract Document and Project Specifications for the <br />HIBBERD PLAZA AND STREETSCAPE (117-063R) <br />CITY DE SOUTH BEND, INDIANA <br />Date: EEBRUARY 26, 201 S <br />EXHIBIT A <br />4-3.11 CIPP <br />-3,11 a NO TIFICA TION A ND PREPARATION <br />1.) AlI residents affected by CIPP activities shall be notified in writing at least 24 hours prior <br />to any service disruption affecting their service connection. Maintenance of service usage <br />shall be provided throughout the duration of the project. <br />2.) Cleaning, video inspection and recording, and inspection of existing sewer shall be <br />conducted prior to installation of the CIPP. Remove all debris, solids, roots, and other <br />deposits from within the pipe that will interfere with the installation of the CIPP. Provide <br />a dumpsite for such debris removed during the cleaning operations. Any damage done to <br />the sewer pipe during cleaning or installation operations shall be the responsibility of the <br />party performing such work. <br />3.) The City Engineer shall be notified of line obstructions, offset joints, collapsed pipe, or any <br />other condition that will prevent the insertion of the tube or significantly reduce the <br />capacity of the sewer. <br />4.) Protruding laterals or services (if found) shall be trimmed flush with the inside of the main <br />sewer wall prior to lining. Trimming shall not cause damage to the lateral or service <br />beyond the inside face of the twain sewer. <br />5.) A maintenance of traffic plan shall be submitted to the City Engineer for review and <br />approval 72 hours before the commencement of CIPP work. <br />4-3.11 (6) TELEVISIONINSPECTION <br />1.) Provide television equipment capable of properly documenting the conditions as found <br />within the pipe in a digital video format (DVD). Lighting for the camera shall illuminate <br />the entire periphery of the sewer. The camera shall be radial view type capable of viewing <br />3601 within the pipe and shall provide an unobstructed view of the full pipe. <br />2.) The video inspection shall begin with a clear identification of the televising location, <br />upstream and downstream manhole designation, and pipe diameter, The DVDs shall <br />provide an accurate length measurement of the entire segment and of the distance to each <br />lateral connection. Pan all lateral connections on both the pre- and post -televising <br />recording. <br />3.) Reverse televising set-ups shall be utilized when line obstructions prevent full segment <br />televising from the initial set-up direction. <br />4.) Both a pre -lining and post -lining DVD shall be submitted to the City Engineer for approval. <br />The DVDs shall be clearly and properly labeled. Inspection for individual sewer segments <br />(manhole to manhole) shall be boolanarked. Pre -lining and Post -lining DVDs and <br />inspection reports shall be submitted to the City Engineer within seven (7) days of <br />inspection. <br />
The URL can be used to link to this page
Your browser does not support the video tag.