Opening of Bids - Granular Activated Carbon Re-Activation & Virgin Replacement - Calgon Carbon Corporation
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2017
>
Opening of Bids
>
Opening of Bids - Granular Activated Carbon Re-Activation & Virgin Replacement - Calgon Carbon Corporation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2025 9:20:24 AM
Creation date
3/15/2017 2:08:35 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
3/14/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
c. Apparent Density: <br />i. The apparent density of the reactivated GAC shall be not less than 0.20 g/cc, <br />as determined in accordance with ASTM D2854/AWWA B604, latest edition. <br />d. Particle Size Distribution: <br />i. Particle size distribution shall be determined in accordance with ASTM <br />2862/AWWA B604, latest edition. The particle size range of the reactivated <br />GAC shall be as specified herein: <br />ii. Mesh Size: 8 x 30 <br />iii. No more than 15% of the reactivated GAC shall be retained on the maximum - <br />size sieve, and no more than 4% of the reactivated GAC shall pass the <br />minimum -size sieve. <br />e. Uniformity Coefficient: <br />i. The reactivated GAC shall have a uniformity coefficient not greater than 2.1. <br />f. Abrasion: <br />i. The retention of mean particle diameter of the reactivated GAC shall not be <br />less than 70% as determined either by the stirring abrasion test or the Ro-Tap <br />abrasion test, AWWA B604, latest edition. <br />g. Performance Criteria: <br />i. Adsorptive Capacity -Iodine Number : <br />1. If the iodine number of the received spent GAC is >550, the reactivated <br />GAC (on a blended basis of reactivated GAC plus virgin make-up GAC as <br />required) shall attain an iodine number at least 800 mg/g, as determined <br />according to ASTM 4607, latest edition. <br />2. If the iodine number of the received spent GAC is <550, the reactivated <br />GAC (on a blended basis of reactivated GAC plus virgin make-up GAC as <br />required) shall attain an iodine number at least 250 mg/g greater than the <br />spent GAC, as determined according to ASTM 4607, latest edition. <br />3. In no case shall the iodine number of the reactivated GAC (on a blended <br />basis of reactivated GAC plus virgin make-up GAC as required) be less <br />than 500 mg/g carbon as determined according to AWWA B604, latest <br />edition. Reactivated GAC, including virgin make-up GAC blended as <br />required, shall meet the following specifications: <br />Ver. 13 — 6101115 <br />